Three-phase power supply
Generator
400V, 3-ph
230V, 3-ph
Rated power [kVA]
13.0
8.5
13.0
8.5
Resistive consum‐
ers [kVA]
–
13.0
8.5
12.7
8.5
Inductive consumers [kW] Rated power
7.5
5.0
12.7
8.5
Tab. 51 Maximum three-phase mains loading
AC power:
Generator
400V, 3-ph
230V, 3-ph
115V, 2-
ph
Rated power [kVA]
13.0
8.5
13.0
8.5
7.0
Resistive consum‐
ers [kVA]
per phase
3.5
–
3.5
–
–
total
10.5
5.0
10.5
5.0
5.0
Inductive consumers [kW] Rated
power
per phase
3.5
–
3.5
–
–
Rated
power
total
10.5
5.0
10.5
5.0
5.0
Tab. 52 Maximum single-phase mains loading
Power reduction at elevated ambient temperatures:
Ambient temperature
[°C]
Generator power
≤30
Full power available
>30
Reduction of 10 % for each temperature rise of 10 °C.
Tab. 53 Power reduction at elevated ambient temperatures
2.8.5 Option ga
Generator (60 Hz version)
Generator specification:
Features
Generator
250V, 2-phase
Rated power [kVA]
2-phase
13.0
8.0
Rated power [kVA]
single-phase
7.0
5.0
Voltage [V]
250/125
Voltage constant [%]
balanced load
±5
2
Technical Specifications
2.8
Options
20
Operator manual Portable compressor
M 64
No.: 9_5898 26 E
RAMIRENT