8.8 Option ga
Generator operation
DANGER
Risk of fatal injury caused by contact with live components!
➤ Check correct function of the insulation monitoring device daily (see chapter 7.5).
➤ Have the generator and control box checked annually by a qualified electrician (see
➤ Follow instructions in chapter 3.8.
8.8.1 Note when operating the generator
Do not exceed the maximum supply system load:
➤ When operating the generator, do not exceed the maximum supply system load due to con‐
nected consumers.
Bear in mind:
■ The power consumption values of simultaneous consumers are added.
■ The maximum continuous power loading on the generator by the connected consumers is
limited by the safety cut-out.
8.8.2 Switching in the generator
Precondition LOAD mode
1. Turn the «generator main switch »to the "l" position.
2. Set the «automatic circuit-breaker(s)» to the "l" position.
3. Turn the mode selector switch to the required mode of operation.
Result The engine runs at maximum speed and the generator generates power.
Further information See chapter 4.6.5.2 for generator controls.
See chapter 4.6.5.1 for generator operating modes.
Connect electrical consumers
1. DANGER!
Devices start automatically without warning.
Serious injury and damage to property is possible.
➤ Make sure that electric consumers are switched off.
8
Operation
8.8
Generator operation
80
Operator manual Portable compressor
M 64