Fig. 28 Control line shut-off valve
1
Compressed air outlet distributor
2
Shut-off ball valve
I – open
0 – closed
1. Open the right-hand access door.
2. Check the shut-off valve in the control line.
Shut-off valve is closed: open the shut-off valve.
The machine is ready for operation.
3. Close the door.
8.2.7 Shutting down the machine
NOTICE
Thermal overload of the turbocharger!
Abrupt stopping of the engine under load can cause a fault or damage to the turbocharger.
➤ Run the engine a few minutes in idle before shutting down to allow the turbocharger to
cool.
Operating the machine in the cool-down phase
1. Close all «compressed air outlet valves» on the air distributor.
The engine runs in IDLE and the turbocharger can cool down.
2. After approx. 2 to 3 minutes, switch the «starter switch» to the "STOP/Off" position.
The engine turns off.
Make sure equipment is protected from venting
Compressed air lines to consumers should not vent when the compressor shuts down.
A typical example would be a user's auxiliary air receiver.
The shut-off valve must remain open for any other applications!
1. Open the right-hand access door.
2. Close the shut-off valve.
Further information Close the shut-off valve in the control line (see Fig. 28).
8
Operation
8.2
Starting and stopping
No.: 9_5898 26 E
Operator manual Portable compressor
M 64
73
RAMIRENT