Grey or brownish exhaust gas
Meaning
Remedy
Where can I get help?
SW
KS
The exhaust contains residues
of hydrocarbons or sulphate.
Have the fuel injection system
checked.
Use an engine oil that produces
low white ash.
X
X
SW = specialised workshop; KS = KAESER SERVICE
Tab. 84 Grey or brownish exhaust gas
9.5 Option ga
Evaluate generator faults and alarms
9.5.1 There is no voltage or too low a voltage from the generator
Possible cause
Remedy
Where can I get help?
SW
KS
Defective drive belt.
Have changed.
X
X
Generator/regulator defective
Have repaired.
X
X
Overload protection switch trig‐
gered because of overload or
defect.
Check the power requirement of
the connected consumers and
reduce if necessary; check the
consumers for short circuits.
X
–
Check the overload protection
switch and have changed if nec‐
essary.
X
X
Engine speed too low.
Have reset to rated speed.
X
X
Generator not switched in.
Switch in the generator.
–
–
The compressor's working pres‐
sure is set too high, engine
overloaded, speed drops off
Have the working pressure ad‐
justed.
X
X
The engine power is reduced
because of climatic or other ef‐
fects.
Keep the generator and com‐
pressor load below the rated
power
–
–
SW = specialised workshop; KS = KAESER SERVICE
Tab. 85 There is no voltage or too low a voltage from the generator
9.5.2 Generator voltage too high
Possible cause
Remedy
Where can I get help?
SW
KS
Generator/regulator defective
Have repaired.
X
X
SW = specialised workshop; KS = KAESER SERVICE