■ Using the machine without an air filter element is not permitted!
■ Do not use an air filter element with damaged folds or gasket.
■ The use of an unsuitable air filter can permit dirt to ingress the pressure system and
cause premature wear and damage to the machine.
Material Compressed air for blowing out
Spare parts (as required)
Wrench
Cleaning cloth
Precondition The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 bar.
Machine is cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
NOTICE
Damaged air filter element.
Machine damage due to contaminated intake air.
➤ Do not try to clean the filter element by striking or knocking it.
➤ Do not wash the filter element.
Fig. 59 Compressor air filter maintenance
1
Filter cap
2
Air filters
3
Maintenance indicator
4
Red zone indicator scale
5
Indicating piston of the maintenance indi‐
cator
6
Reset knob for the maintenance indicator
7
Loosen the screws
10 Maintenance
10.4 Compressor Maintenance
134
Operator manual Portable compressor
M 64
No.: 9_5898 26 E