4 Mounting
4.5.3
Metal pipe with loose flanges
Using the example of the dual-compartment transmitter housing
1. Weld the threaded bolts M6 (1) to the pipeline and establish the ground connection as shown in the
illustration.
2. Establish the connection between the ground terminal (2) of the sensor and a suitable grounding
point using a copper wire [at least 2.5 mm
2
(14 AWG)] according to the figure.
4.5.4
Sensor model 406015 and 406016
Using the example of the dual-compartment transmitter housing
The grounding is established as displayed in the figure. The measurement medium is grounded via the
adapter (1) so that an additional grounding is not required.
An additional grounding is only required for the "wafer" process connection
See figures
chapter 4.5.2 "Metal pipe with fixed flanges", page 48 and chapter 4.5.3 "Metal pipe with loose flanges",
page 49.
Flange version
Model 406012, 406013, 406015 and 406016
Connection flange design
Model 406015 and 406016
(1)
Threaded bolts
(2)
Ground terminal
(1)
(2)
(1)
(2)
(1)
Adapter
(1)
Summary of Contents for flowTRANS MAG H01
Page 2: ......
Page 22: ...1 Safety 22...
Page 68: ...5 Electrical connection 68...
Page 72: ...6 Digital communication 72...
Page 94: ...7 Startup 94...
Page 108: ...8 Parameterization 108...
Page 109: ...109 8 Parameterization...
Page 110: ...8 Parameterization 110...
Page 111: ...111 8 Parameterization...
Page 112: ...8 Parameterization 112...
Page 152: ...8 Parameterization 152...
Page 160: ...9 Advanced diagnostics functions 160...
Page 258: ...14 Annex 258...
Page 259: ......