– 71 –
1. Adjusting the lateral position
Adjust so that the right-hand end of the elastic band meets the left-
hand side of collar
of the front roller and collar
of the
intermediate roller when putting straight the elastic band on the front
roller. Adjust in accordance with the procedure below.
(1) Loosen two screws
, adjust elastic band guide
to the elastic
band width, and tighten two screws
.
(2) Loosen screw
, adjust collar
to the position of the right-hand
end of elastic band, and tighten screw
.
(3) Loosen screw
in collar
of the intermediate roller, and move
collar
to the right or left in accordance with the elastic band width.
At this time, make sure that the elastic band is put straight. Then
tighten screw
.
(Caution) Do not excessively tighten screws
and
.
Deformation of collars
and
will be caused.
2. Adjusting the vertical position
Loosen clamp lever
, and adjust the height of front roller
.
Adjust the position in accordance with the length of the elastic band,
and tighten clamp lever
.
Adjustment Procedure
Results of Improper Adjustment
E10
Summary of Contents for MF-7800D Series
Page 64: ...60 5 Adjusting the upper knife stroke A B Standard Adjustment H21...
Page 66: ...62 MEMO...
Page 80: ...76 3 Adjusting the elastic band presser plate 0 5mm Standard Adjustment E10 A A Approx 7 5 mm...
Page 84: ...80 MEMO...
Page 94: ...90 3 Setting of SC 510 2 Change of the setting Type B Type A Standard Adjustment UT25...
Page 114: ...110 MEMO...
Page 118: ...114 2 Installing SC 510 1 Wiring SC 510 Standard Adjustment UT22...
Page 124: ...120 MEMO...
Page 134: ...130 MEMO...
Page 142: ...138 7 Feed timing of the roller A Standard Adjustment PL11 C D B...