– 25 –
1. Remove rubber cap
in the face plate, loosen setscrew
in the
needle bar bracket and adjust the height of the needle bar.
2. After adjusting the height, equally adjust the clearance A between
needle
and needle hole
in the throat plate and fix the needle
bar with setscrew
in the needle bar bracket.
o When the height of the needle
is excessively different, stitch
skipping, needle breakage,
thread breakage, etc. will be
caused.
A
Equal
Adjustment Procedure
Results of Improper Adjustment