– 41 –
1. Adjusting the height of the presser foot
Loosen adjustment nut
. Lower lifter lever
, adjust height
adjustment screw
, and fix nut
at the position where the presser
foot does not come in contact with other components.
2. Adjusting the thrust collar
Loosen setscrew
in the thrust collar and adjust the clearance.
When the height of the presser foot is changed, Be sure to perform
the adjustment of the clearance of thrust collar
and check the
clearance.
3. Adjusting the lifter connecting plate
For the adjustment of the clearance provided between lifter
connecting plate
and hinge screw
, loosen setscrew
in the
lifter lever shaft when the feed dog lowers from the top surface of
the throat plate and the bottom face of the presser foot comes in
close contact with the throat plate.
o When the position of the presser
foot is too high, it comes in con-
tact with the spreader, and break-
age, stitch skipping, etc. will be
caused.
In addition, the needle tip comes
out from the sole of the presser
foot. As a result, sewing material
is damaged or needle breakage
will be caused.
o In case the clearance of thrust
collar
is large, when the
presser foot gets over the
overlapped section, the presser
foot comes in contact with other
components and will cause the
damage.
o When replacing the presser foot
due to the replacement of the
gauge or the like, check the
clearance provided between
t h r u s t c o l l a r
a n d l i f t e r
connecting plate
.
o When the clearance of lifter
connecting plate
does not
exist, not only feed force is
reduced but also components
are led to breakage since the
presser foot does not come down
to the top surface of the throat
plate when the feed dog comes
down from the top surface of the
throat plate.
o When adjusting the lever shaft,
adjust the height of lifter lever
.
Adjustment Procedure
Results of Improper Adjustment
Summary of Contents for MF-7800D Series
Page 64: ...60 5 Adjusting the upper knife stroke A B Standard Adjustment H21...
Page 66: ...62 MEMO...
Page 80: ...76 3 Adjusting the elastic band presser plate 0 5mm Standard Adjustment E10 A A Approx 7 5 mm...
Page 84: ...80 MEMO...
Page 94: ...90 3 Setting of SC 510 2 Change of the setting Type B Type A Standard Adjustment UT25...
Page 114: ...110 MEMO...
Page 118: ...114 2 Installing SC 510 1 Wiring SC 510 Standard Adjustment UT22...
Page 124: ...120 MEMO...
Page 134: ...130 MEMO...
Page 142: ...138 7 Feed timing of the roller A Standard Adjustment PL11 C D B...