(6) Adjusting the spreader
1. Height of the spreader
It is the standard that the height from the top surface of throat plate
to the bottom surface of spreader
is 7.8 to 8.2 mm.
7.8 to 8.2mm
0.1 to 0.3mm
A
Standard Adjustment
2. Longitudinal position of the spreader
It is the standard that when spreader
returns from the extreme left position to the right and top end
A
of
thread hooking section reaches to the front of left needle, the clearance between the spreader and the left
needle is 0.1 to 0.3 mm.
3. Protruding amount
It is the standard that the dimension from the center of left needle to top end
A
of thread hooking section,
when spreader
is in the extreme left position, is 4.5 to 5.5 mm.
4. Spreader stroke
It is the standard that the spreader stroke is 17.0 to 18.0 mm at the stroke of thread hooking section.
5. Timing of the spreader
Standard position is the position where the spreader
is in the extreme left position when the needle bar
comes down from the upper dead point by 1.1
±
0.1 mm.
A
4.5 to 5.5mm
17.0 to 18.0mm
Extreme
left position
Summary of Contents for MF-7800D Series
Page 64: ...60 5 Adjusting the upper knife stroke A B Standard Adjustment H21...
Page 66: ...62 MEMO...
Page 80: ...76 3 Adjusting the elastic band presser plate 0 5mm Standard Adjustment E10 A A Approx 7 5 mm...
Page 84: ...80 MEMO...
Page 94: ...90 3 Setting of SC 510 2 Change of the setting Type B Type A Standard Adjustment UT25...
Page 114: ...110 MEMO...
Page 118: ...114 2 Installing SC 510 1 Wiring SC 510 Standard Adjustment UT22...
Page 124: ...120 MEMO...
Page 134: ...130 MEMO...
Page 142: ...138 7 Feed timing of the roller A Standard Adjustment PL11 C D B...