– 146 –
2-G) Needle thread guard
G-1) Being used.
Do not use.
2-H) Spreader
H-1) Spreader thread tension is too
Reduce the tension.
strong.
2-I)
Needle heat
I-1) Stitch skip occurs before thread
Same described in page "Thread breakage by
breakage produced by needle heat.
needle heat"
2-J) Looper adjustment
J-1) Incorrect clearance adjustment,
Refer to the standard adjustment figures.
incorrect returning amount
adjustment
2-K) Needle guard, front and
K-1) Incorrect contact amount,
Refer to the standard adjustment figures.
rear
incorrect height
5-3) Looper does not scoop
3-A) Looper
A-1) Incorrect shape of pointed end of
Replace it with the genuine part.
the left needle thread.
looper disables scooping a loop.
3-B) Needle
B-1) Needle bend, incorrect needle
Replace the needle with new one, Correct the
mounting direction, wrong needle
mounting direction, Use UY128GAS.
3-C) Auxiliary thread tension
C-1) Being used.
Do not use nipper.
adjustment
3-D) Needle thread guide rod
D-1) Height is too low.
Correct height position to appropriate height.
3-E) Needle height
E-1) Height is too low.
Refer to standard adjustment.
3-F) Threading
F-1) Incorrect threading
Refer to threading diagram.
3-G) Needle guard
G-1) Being used.
Do not use.
3-H) Spreader
H-1) Too near to the left needle
Refer to the standard adjustment figures.
3-I)
Needle heat
I-1) Stitch skip occurs before thread
Same described in page "Thread breakage by
breakage produced by needle heat.
needle heat"
3-J) Looper adjustment
J-1) Incorrect clearance adjustment,
Refer to the standard adjustment figures.
incorrect returning amount
3-K) Needle guard, front and
K-1) Incorrect contact amount, incorrect
Refer to the standard adjustment figures.
rear
height
From the previous page
To the next page
Trouble (1)
Trouble (2)
Cause (1)
Cause (2)
Corrective measures
From the previous page
Left
Right
Left
Right
Summary of Contents for MF-7800D Series
Page 64: ...60 5 Adjusting the upper knife stroke A B Standard Adjustment H21...
Page 66: ...62 MEMO...
Page 80: ...76 3 Adjusting the elastic band presser plate 0 5mm Standard Adjustment E10 A A Approx 7 5 mm...
Page 84: ...80 MEMO...
Page 94: ...90 3 Setting of SC 510 2 Change of the setting Type B Type A Standard Adjustment UT25...
Page 114: ...110 MEMO...
Page 118: ...114 2 Installing SC 510 1 Wiring SC 510 Standard Adjustment UT22...
Page 124: ...120 MEMO...
Page 134: ...130 MEMO...
Page 142: ...138 7 Feed timing of the roller A Standard Adjustment PL11 C D B...