– 8 –
(2) Adjusting the rocking thread take-up
1. Length of the rocking thread take-up
(1) Dimension A from the center of the shaft to the thread hole face of rocking thread take-up
is the standard
length of rocking thread take-up
.
2. Position of the rocking thread take-up
(1) Install so that rocking thread take-up
is flush when the needle bar is in its lowest position.
3. Timing of the rocking thread take-up
(1) It is the standard timing that rocking thread take-up
is in
its lowest position as well when the needle bar is in its lowest
position.
Timing of rocking thread take-up
is performed by
adjusting the position of rocking thread take-up ball arm
.
4. Relation between the timing of rocking thread take-up and
the needle thread loop
(1) When using the excessively stretchable thread or the hard-
to-stretch thread, the size of needle thread loop can be
changed by changing the timing of rocking thread take-up
.
(2) Relation between the timing of the rocking thread take-up
and the size of needle thread loop is as shown in the
table on the next page.
(The relation becomes reverse when using the needle bar
thread take-up = standard seams and when it is not used =
soft seams. So, be careful.)
A
4mm
A
Standard Adjustment
↑
Anti-operator’s side
Operator’s side
↓
Dimension A
Standard seams
90
Soft seams
98
Unit : mm
Flush
Summary of Contents for MF-7800D Series
Page 64: ...60 5 Adjusting the upper knife stroke A B Standard Adjustment H21...
Page 66: ...62 MEMO...
Page 80: ...76 3 Adjusting the elastic band presser plate 0 5mm Standard Adjustment E10 A A Approx 7 5 mm...
Page 84: ...80 MEMO...
Page 94: ...90 3 Setting of SC 510 2 Change of the setting Type B Type A Standard Adjustment UT25...
Page 114: ...110 MEMO...
Page 118: ...114 2 Installing SC 510 1 Wiring SC 510 Standard Adjustment UT22...
Page 124: ...120 MEMO...
Page 134: ...130 MEMO...
Page 142: ...138 7 Feed timing of the roller A Standard Adjustment PL11 C D B...