(3) Adjusting the needle and the needle guide
[The position of the needle and the throat plate]
[The clearance between the needle and the needle guide]
(4) Adjusting the position of the york slide
Standard Adjustment
Standard Adjustment
Center
0 to 0.1mm
Approx.
6mm
0 to 0.2mm
To align
0.2 to 0.4mm
A
Locus of york slide
On the same line
A
B
Blade tip
of looper
Engraved line
Electronic pen mark
Summary of Contents for AMB-289
Page 11: ...7 MEMO...
Page 16: ...12 5 Wiper adjustment Wiper components 3 to 5mm 6 to 8mm Standard Adjustment...
Page 18: ...14 6 Adjusting the face plate thread tension A 12mm Standard Adjustment...
Page 22: ...18 8 Adjusting the position of Y top feed motor Standard Adjustment...
Page 24: ...20 9 Adjusting the position of Y bottom feed motor Standard Adjustment...
Page 26: ...22 10 Adjusting the tongue up down cylinder 19mm 5mm Gauge A Standard Adjustment...
Page 30: ...26 12 Adjusting the differential feed X top feed motor 6 0 5mm Align Standard Adjustment...
Page 36: ...32 15 Adjusting the chuck open close cylinder Standard Adjustment 26 0 5mm...
Page 42: ...38 16 Adjusting the respective sensors 3 3 C Standard Adjustment 14 5 0 5mm...
Page 48: ...44 2 Disassembling and assembling of the face plate Procedures of disassembling assembling...
Page 62: ...58 8 Replacing the thread trimmer cylinder 4 5mm Procedures of disassembling assembling...
Page 68: ...64 11 Replacing the thread drawing motor A B C C Procedures of disassembling assembling...
Page 70: ...66 12 Replacing the loader motor Procedures of disassembling assembling...
Page 81: ...77 MEMO...
Page 172: ...168 MEMO...
Page 176: ...172 MEMO...