– 128 –
(4) Changing the voltage of 100 / 200V
It is adaptable to the voltage of single phase 100V to 120V/3-phase 200V to 240V by changing the voltage changeover
connector mounted on FLT p.c.b.
(Caution) When the changing procedure is wrong, the control box will be broken. So, be very careful.
Changing procedure of the changeover connector
1. Turn OFF the power source with the power switch
after confirming that the sewing machine has
stopped.
2. Draw out the power cord from the power plug
socket after confirming that the power switch is
turned OFF. Then wait for five minutes or more.
3. Remove the front cover.
4. Remove four screws fixing the rear cover of the
control box and slowly open the rear cover.
A. In case of using with 3-phase 200V to 240V
•
Changing the changeover connector
Connect to 200V the 100/200V changeover con-
nector of FLT p.c.b.
located on the side of the
Box Side of the control box.
•
Connect the crimp style terminal of AC input cord
to the power plug as shown in the figure.
B. In case of using with single phase 100V to
120V
•
Changing the changeover connector
Connect to 100V the 100/200V changeover con-
nector of FLT p.c.b.
located on the side of the
Box Side of the control box.
•
Connect the crimp style terminal of AC input cord
to the power plug as shown in the figure.
(Caution) Securely perform the insulation treat-
ment to the red terminal which is not
used with insulation tape or the like.
(When the insulation is insufficient,
there is a danger of electric shock or
leakage current.)
C. In case of using with single phase 200V to
240V
• Changing the changeover connector
Connect to 200V the 100/200V changeover con-
nector of FLT p.c.b.
located on the side of the
Box Side of the control box.
•
Connect the crimp style terminal of AC input cord
to the power plug as shown in the figure.
(Caution) Securely perform the insulation treat-
ment to the red terminal which is not
used with insulation tape or the like.
(When the insulation is insufficient,
there is a danger of electric shock or
leakage current.)
5. Check that the change has been performed with-
out fail before closing the rear cover.
6. Be careful that the cord is not pinched between
the rear cover and the control box main unit.
Close the rear cover while pressing the lower side
of rear cover, and tighten four screws.
GREEN/
YELLOW
(Plug side)
WHITE
BLACK
RED
WHITE
BLACK
RED
GREEN/
YELLOW
A
GREEN/
YELLOW
GREEN/
YELLOW
(Plug side)
WHITE
BLACK
RED
WHITE
BLACK
RED
B
GREEN/
YELLOW
(Plug side)
GREEN/
YELLOW
C
WHITE
BLACK
RED
WHITE
BLACK
RED
Summary of Contents for AMB-289
Page 11: ...7 MEMO...
Page 16: ...12 5 Wiper adjustment Wiper components 3 to 5mm 6 to 8mm Standard Adjustment...
Page 18: ...14 6 Adjusting the face plate thread tension A 12mm Standard Adjustment...
Page 22: ...18 8 Adjusting the position of Y top feed motor Standard Adjustment...
Page 24: ...20 9 Adjusting the position of Y bottom feed motor Standard Adjustment...
Page 26: ...22 10 Adjusting the tongue up down cylinder 19mm 5mm Gauge A Standard Adjustment...
Page 30: ...26 12 Adjusting the differential feed X top feed motor 6 0 5mm Align Standard Adjustment...
Page 36: ...32 15 Adjusting the chuck open close cylinder Standard Adjustment 26 0 5mm...
Page 42: ...38 16 Adjusting the respective sensors 3 3 C Standard Adjustment 14 5 0 5mm...
Page 48: ...44 2 Disassembling and assembling of the face plate Procedures of disassembling assembling...
Page 62: ...58 8 Replacing the thread trimmer cylinder 4 5mm Procedures of disassembling assembling...
Page 68: ...64 11 Replacing the thread drawing motor A B C C Procedures of disassembling assembling...
Page 70: ...66 12 Replacing the loader motor Procedures of disassembling assembling...
Page 81: ...77 MEMO...
Page 172: ...168 MEMO...