– 104 –
d
d
Screen during data writing
Screen of end data writing
Data writing abnormal screen
If the screen below is displayed, quickly
turn OFF the power and perform the
setup again after checking [Checking
items] below.
The procedure above com-
pletes the replacing work of
application software.
Checking items
1
Smart media cover is opened during the data communication from the smart media.
2
Data of the smart media is not correct. Or, there is no data file.
3
Contact of the smart media is dirty. Contact is defective.
(Caution) Do not turn OFF the power and close/open the smart media cover during the work.
The main unit may be broken.
Summary of Contents for AMB-289
Page 11: ...7 MEMO...
Page 16: ...12 5 Wiper adjustment Wiper components 3 to 5mm 6 to 8mm Standard Adjustment...
Page 18: ...14 6 Adjusting the face plate thread tension A 12mm Standard Adjustment...
Page 22: ...18 8 Adjusting the position of Y top feed motor Standard Adjustment...
Page 24: ...20 9 Adjusting the position of Y bottom feed motor Standard Adjustment...
Page 26: ...22 10 Adjusting the tongue up down cylinder 19mm 5mm Gauge A Standard Adjustment...
Page 30: ...26 12 Adjusting the differential feed X top feed motor 6 0 5mm Align Standard Adjustment...
Page 36: ...32 15 Adjusting the chuck open close cylinder Standard Adjustment 26 0 5mm...
Page 42: ...38 16 Adjusting the respective sensors 3 3 C Standard Adjustment 14 5 0 5mm...
Page 48: ...44 2 Disassembling and assembling of the face plate Procedures of disassembling assembling...
Page 62: ...58 8 Replacing the thread trimmer cylinder 4 5mm Procedures of disassembling assembling...
Page 68: ...64 11 Replacing the thread drawing motor A B C C Procedures of disassembling assembling...
Page 70: ...66 12 Replacing the loader motor Procedures of disassembling assembling...
Page 81: ...77 MEMO...
Page 172: ...168 MEMO...
Page 176: ...172 MEMO...