Z2 Controller Operations Manual
Interoperability Now
5-19
Z2C Installation and Operation Manual
Figure 5-16: Configure Recorder Channel
The Recorder interface on the Z2C currently only supports unicast RTP connections. JPS has
partnered with the Stancil Corporation to test and verify functionality with the Stancil Logging
Recorder; however, other recorders that support unicast RTP streams should function with little
to no issue.
In the following example, we will configure recording channels on the Stancil Logging Recorder
Channel Configuration prior to configuring the Recorder channels on the Z2C. In the screenshot
shown below, we have configured a channel using the PCMU (G711_ULAW) vocoder using
Port 9004 on the IP Recorder located at 192.168.1.60.