Figure 70. Initialize Array Set Window
Information box - Displays a summary about initializing an array with
a note that this is a long process and data will be destroyed.
Device Information - Displays a summary of the array selected to be
initialized.
Name - ComArray2, the name given when the array was created.
RAIDLevel - RAID 5, the RAID level shown in this example.
Current Size - 68.31 GB, the size of the array used in this example.
OK - Click OK to begin this operation.
Cancel - Click Cancel to stop this operation.
Manually Rebuilding an Array
A manual rebuild or an auto rebuild is a background process that is effective for
all RAID levels except RAID 0. The rebuild activity will reconstruct data and
parity on a replacement member drive when one of the member drives of a
redundant array set fails. System performance will be impacted during rebuilds.
A manual rebuild is required if there are no spares (dedicated or global) in the
enclosure; otherwise, auto rebuild will begin immediately. For more information
about spares and auto rebuild, please see