SECTION 4 - BOOM & PLATFORM
4-70
3121234
4.14 SKYGUARD
Operation
Skyguard is used to provide enhanced control panel protection.
When the SkyGuard sensor is activated, functions that were in
use at the time of actuation will reverse or cutout.
Functional Test
IF SKYGUARD SYSTEM IS INSTALLED ON MACHINE &
“SKYGUARD” IS SELECTED IN MACHINE SET UP.
In Platform Mode:
1.
In an area free of obstructions, from the platform con-
trols test the SkyGuard feature by operating the tele-
scope out functions and engaging (and holding) the
SkyGuard sensor. Telescope function will be stopped
and telescope in function will be activated for a short
duration. Soft touch indicator light will flash at 3HZ,
horn will be turned on, until the SkyGuard sensor and
footswitch is disengaged.
2.
With SkyGuard sensor engaged, press and hold the
yellow “Override Soft Touch” button and then operate a
function switch or joystick to check if the operation can
be resumed.
3.
Disengage the SkyGuard sensor, release controls, recycle
the foot switch, make sure normal operation available.
In Ground Mode:
Operation will be allowed regardless of SkyGuard sensor activa-
tion.
IF SKYGUARD SYSTEM IS INSTALLED ON MACHINE &
“BOTH” IS SELECTED.
In Platform Mode:
NOTE:
Machine will treat Soft Touch/SkyGuard override switch as
if it is a Soft Touch and SkyGuard switch.
1.
In an area free of obstructions, from platform controls
test the SkyGuard feature by operating the telescopic
out functions and engaging the SkyGuard sensor, tele-
scopic out function will be stopped, soft touch indicator
light will flash at 3HZ, the horn will be turned on until
the SkyGuard sensor and footswitch is disengaged.
2.
With SkyGuard sensor engaged, press and hold the yel-
low “Override Soft Touch” button and then operate a
function switch or joystick to check if the operation can
be resumed.
3.
Disengage the SkyGuard sensor, release controls, recycle
the foot switch, make sure normal operation is available.
In Ground Mode:
Operation will be allowed regardless of SkyGuard switch activa-
tion.
IF SKYGUARD SYSTEM IS INSTALLED ON MACHINE &
“SOFT TOUCH” IS SELECTED.
Machine will treat the Soft Touch/SkyGuard override switch as if
it is a Soft Touch switch.
IF SKYGUARD SYSTEM IS INSTALLED ON MACHINE &
“NONE” IS SELECTED.
Skyguard sensor status will be ignored. No function cutout or
reversal will be implemented.
Figure 4-26. Skyguard
Summary of Contents for 680S
Page 2: ......
Page 52: ...SECTION 2 GENERAL 2 14 3121234 NOTES...
Page 55: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 3 This page left blank intentionally...
Page 89: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 37 Figure 3 28 Assembly Tools Seal Pressing...
Page 139: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 87 Figure 3 62 Swing Hub Prior to SN 0300134352...
Page 143: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 91 Figure 3 64 Swing Brake...
Page 205: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 153 This page left blank intentionally...
Page 208: ...SECTION 3 CHASSIS TURNTABLE 3 156 3121234 Figure 3 91 Generator Electrical Circuit Diagram...
Page 224: ...SECTION 3 CHASSIS TURNTABLE 3 172 3121234 Figure 3 103 EMR 2 Engine Side Equipment...
Page 225: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 173 Figure 3 104 Deutz EMR 2 Troubleshooting Flow Chart...
Page 229: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 177 Figure 3 108 EMR 2 Engine Plug Pin Identification...
Page 230: ...SECTION 3 CHASSIS TURNTABLE 3 178 3121234 Figure 3 109 EMR 2 Vehicle Plug Pin Identification...
Page 231: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 179 Figure 3 110 EMR2 Fault Codes Sheet 1 of 5...
Page 232: ...SECTION 3 CHASSIS TURNTABLE 3 180 3121234 Figure 3 111 EMR2 Fault Codes Sheet 2 of 5...
Page 233: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 181 Figure 3 112 EMR2 Fault Codes Sheet 3 of 5...
Page 234: ...SECTION 3 CHASSIS TURNTABLE 3 182 3121234 Figure 3 113 EMR2 Fault Codes Sheet 4 of 5...
Page 235: ...SECTION 3 CHASSIS TURNTABLE 3121234 3 183 Figure 3 114 EMR2 Fault Codes Sheet 5 of 5...
Page 264: ...SECTION 3 CHASSIS TURNTABLE 3 212 3121234 NOTES...
Page 285: ...SECTION 4 BOOM PLATFORM 3121234 4 21 This page left blank intentionally...
Page 333: ...SECTION 4 BOOM PLATFORM 3121234 4 69 Figure 4 25 Load Sensing Device...
Page 336: ...SECTION 4 BOOM PLATFORM 4 72 3121234 NOTES...
Page 416: ...SECTION 5 BASIC HYDRAULICS INFORMATION SCHEMATICS 5 80 3121234 NOTES...
Page 423: ...SECTION 6 JLG CONTROL SYSTEM 3121234 6 7 Figure 6 2 ADE Block Diagram...
Page 480: ...SECTION 6 JLG CONTROL SYSTEM 6 64 3121234 NOTES...
Page 528: ...SECTION 7 BASIC ELECTRICAL INFORMATION SCHEMATICS 7 48 3121234 NOTES...
Page 529: ......