IN-WALL INSTALLATION
Type: IW-1
Evaluating the Wall Cavity
The ICS enclosure can be mounted
in between two studs, within a wall
cavity, constructed from 2 x 6 studs
or larger. Once installed, anything
coming into contact with it can lead
to unwanted vibrations and rattles
that cannot be accessed/corrected
after the installation.
(Figure 21)
Before proceeding, verify that your
wall cavity meets these requirements:
• At least 58-inches of
unobstructed height
(measured from the floor)
• Continuous width inside the
studs, over the entire 58-inches
must be no less than 14 ½-inches
and no greater than 15 ½-inches.
• A minimum 5 ½-inches of depth
• Studs on either side of the
wall cavity should be straight,
plumb and parallel, without any
twisting or bowing.
• If your stud bay has any
obstructions, such as wiring,
conduits or cross-members,
you’ll need to discuss removing
or relocating them with your
general contractor, or you will
need to choose a different
stud bay.
58-inches
minimum
5.50-inches
minimum
14.50 to
15.50-inches
Figure 21