126
UMG 96RM-PN
Basic functions quick guide
Modify current transformer setting
Switch to Programming mode:
• Switching to Programming mode is done by pressing
buttons 1 and 2 simultaneously for approx. 1 second.
The symbols for Programming mode "PRG", and for
the current transformer "CT" appear.
• The selection is confirmed with button 1.
• The first digit of the input range for the primary current
flashes.
Modify primary current
• Modify the flashing digit with button 2.
• Use button 1 to select the next number you wish to
modify. The selected digit to be modified flashes. If
the entire number flashes, the decimal point can be
moved with button 2.
Modify secondary current
• Only 1A or 5A can be set as the secondary current.
• Use button 1 to select the secondary current.
• Modify the flashing digit with button 2.
Exit Programming mode
• Switching to Display mode is done by pressing buttons
1 and 2 again simultaneously for approx. 1 second.
Retrieving measured values
Switch to Display mode:
• If Programming mode is still active (PRG and CT
symbols shown on the display), pressing buttons 1 and 2
simultaneously for approx. 1 second switches to Display
mode.
• A measured value screen, e.g. for the voltage, appears
Current transformer symbol
(only in Programming mode)
Current transformer setting,
primary current
Programming mode
indicator
Current transformer setting,
secondary current
Button control
• Button 2 is used to switch
between the measured
value screens for current,
voltage, power, etc.
• Button 1 is used to switch
between the mean values, max
values, etc. associated with a
particular measured value.