12.5. Phone number entering
sequence: 06
Monitoring station modem phone numbers can be stored by entering the following sequence:
0 6 x x .... x F y
xx...x
- Monitoring Station phone number (up to 16 digits)
y
is 1 for main phone number memory
2 for back up phone number memory
Pause
(3 sec.) can be inserted into the telephone number by entering
F0
. It is also possible to insert the
∗
tone by
F7
or
the
#
tone by
F8
if requested for
DTMF dialing.
Example: number 02 123456 as main Monitoring Station number is entered with 06 02 F0 123456 F1.
Phone number erasing
0 6 F 0 F y
y
is 1 to erase the main telephone number
2 to erase the back up telephone number
Note: Changing of a phone number erases the internal communicator’s memory of non reported events and sends a
„Reset“ reporting code (051) to the Monitoring Station.
Factory setting: both numbers are erased
12.6. Digital communicator reset
sequence: 096060
By entering this sequence the factory default settings of all parameters are restored. All phone numbers, reporting codes,
account codes etc. are erased. This reset doesn’t effect the voice dialer’s settings. The reset sequence is:
0 9 6060
Note: All communicator settings are normally stored in non-volatile memory and remain unchanged even after switching
off the power supply.