Alarm system JA-60 "COMFORT"
- 14 -
MDY51319
where x
represents the following functions (non split system):
0 Chime
– triggered during the entrance delay (pre-alarm output)
1 Fire
– triggered by a fire alarm (by a smoke or a gas detector)
2 Arm
– activated when the control panel is armed (complete & partial arming)
3 Panic
– activated when a silent panic alarm is triggered
4 Alarm
– triggered by any audible alarm (except panic alarm)
5 Door
– activated for 5sec. after F3 entering (electric door lock opening)
6 Home
– activated when the control panel is partially armed (Home arming)
7 No AC
– triggered by an AC power failure
8 Phone
– output can be operated remotely by phone or by SMS (if this feature is
supported by installed communicator) or locally from the keypad by F81 (ON) and F80 (OFF).
Table for split system:
x
23x (PgX) 24x (PgY)
0
Alarm A
Alarm A
1
Alarm B
Alarm B
2
Chime A Chime A
3
Chime B Chime B
4
Arm A
Arm B
5
Door A
Door B
6
Panic A
Panic B
7 FIRE NoAC
8 Phone Phone
Example for non split system: the PgX will work as a Panic output when 233 is entered, PgY as Door output when 245 is en-
tered.
Factory default setting: PgX=Chime, PgY=Arm
Note: the control panel also wirelessly transmits the PgX and PgY signals. Wireless output modules UC-216 and UC-222 can be used
to receive the signals. The function of the UC module output relays is determined by the 23x and 24x setting.
8.7. User recorded message and phone numbers editing in the user mode sequence: 2 5 x
The User mode, which is accessible with F 0 “Master Code”, is for battery replacement and system testing. This setting
enables the user to change the voice message and telephone numbers of the built in dialer. If the changes are enabled,
then programming sequences 7=tel. numbers programming, 8=voice message recording and 89=dialer testing are ac-
cessible in the
U
ser mode (see description from 9.1. to 9.3.).
options:
2 5 1
changes
enabled
2 5 0
changes
disabled
(no programming in the
U
ser mode)
Factory default setting: changes disabled
8.8. Radio signal jamming testing
sequence: 2 6 x
When this function is enabled, the control panel will indicate trouble if the working band is jammed for more than 30 sec-
onds. Jamming will trigger an alarm when the control panel is armed.
options:
2 6 1
testing
enabled
2 6 0
testing
disabled
Factory default setting: disabled
Note: in some locations the system can be repeatedly jammed for some period of time (near radar, TV station etc.). In these cases the
JA-60 system can work without any problems because all important data is repeated, but the jamming test should not be enabled. The
level of the signals and interference can be observed using the Comlink software (see 14.)
8.9. Regular communication checking
sequence: 2 7 x
The control panel will check communication regularly with all enrolled items (detectors, keypads, siren etc.) when this
function is enabled. If communication is lost with any item, the control panel will indicate the fault of this item (when
armed it will also trigger an alarm).
options:
2 7 1
checking
enabled
2 7 0
checking
disabled
Factory default setting: checking disabled
Note: in some locations with a strong radio interference (near radar, TV station etc.) the communication can be jammed periodically.
The control panel can detect such a strong interference as a temporary loss of communication with an item. Even in this case, the JA-
60 system is usually able to work without any problems, because all important data is repeated, but the communication check should
not be used.
8.10. Reset enabled
sequence: 2 8 x
The factory default reset (see 11.) can be disabled. This way no unauthorized future programming of the control panel will
be possible.