Alarm system JA-60 "COMFORT"
- 17 -
MDY51319
8.20. Wireless siren alarm
sequence: 3 8 x
The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor
siren chirp sounds function if enabled in the siren.
options:
3 8 1
siren
enabled
3 8 0
siren
disabled
Factory default setting: siren enabled
8.21. Indication of system problems when arming
sequence: 3 9 x
The system regularly checks the conditions of all items (detectors, keypads etc.). This setting ensures that the user will
be warned with 4 rapid beeps after arming, if any component of the system is not ready for arming. Cause of the problem
(for example permanently triggered detector, lost communication etc.) will remain displayed on the control panel. If the
user ignores this warning, the system will arm after the exit delay, then an alarm will be triggered and finally the problem-
atic item will be bypassed for this arming period. After disarming in such a mode, three beeps will be generated as well.
When the indication is not selected, the problematic item will be bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during arming (for example your main door is not closed), the bypass
of this detector will be canceled automatically and the detector will be ready to trigger an alarm after it is activated (if you
close the door after the system is armed).
options:
3 9 1
warning
enabled
3 9 0
warning
disabled
Factory default setting: warning disabled
8.22. Control panel splitting
sequence: 690 x
The control panel can be split in to 2 independent sections A and B, with a shared common area C. This way the sys-
tem can be operated by two independent user groups. In fact the system in this mode works like two independent sys-
tems. If the system is split to the sections with this setting, it is possible to address detectors, user codes and remote
controls to the above sections (see. 8.22, 23 and 24.).
options:
6 9 0 0
no splitting
(partial arming available in this mode)
6 9 0 1
splitting to sections A, B and common C
(C is armed only when both A and B are armed)
Factory default setting: no splitting
8.23. Addressing of detectors to sections
sequence: 61 nns
If the control panel is split (see 8.21.), the detectors can be addressed to sections by entering:
61 nns
where:
nn
= wireless detector zone number: from 01 to 16
s
= section: 1 = A, 2 = B, 3 = C (common section - it is armed only when both A and B are armed). If the
control panel is not split, and s=2 (or s=3) is selected, this detector will be bypassed while partial arm-
ing.
Example: to address detector zone number 3 to section A enter: 61 031
Factory default setting: detectors 1 - 10 are addressed to A, detectors 11 - 16 are addressed to B
8.24. Addressing of the user codes to sections
sequence: 62 nns
If the control panel is split (see 8.21.), the user codes can be addressed to sections A or B by entering:
62 nns
where:
nn
= user code number: from 01 to 14
s
=section: 1 = A, 2 = B