8.15. Exit delay audible indication
sequence: 3 3 x
The exit delay can be indicated by the „beeping“ of the control panel (for the last five seconds, the beeping is faster). The
audible indication can be disabled with this setting.
options:
3 3 1
indication
enabled
3 3 0
indication
disabled
Factory default setting: indication enabled
8.16. Partial arming exit delay audible indication
sequence: 3 4 x
Partial arming with F2 provides an exit delay for delayed reaction detectors in positions 1 to 10. The exit delay for partial
(split) arming can be indicated by the „beeping“ of the control panel (for the last five seconds the beeping is faster).
options:
3 4 1
indication
enabled
3 4 0
indication
disabled
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming and disarming will automatically be silent, regardless of the 36x setting.
8.17. Entrance delay audible indication
sequence: 3 5 x
The entrance delay can be indicated by a rapid „beeping“ of the control panel. This indication can be disabled with this
setting.
options:
3 5 1
indication
enabled
3 5 0
indication
disabled
Factory default setting: indication enabled
8.18. Arming and disarming chirp sounds
sequence: 3 6 x
The control panel confirms arming with a beep and disarming with two beeps (3 beeps after disarming indicates user
information on the LED display). 4 beeps indicates that a bypass is activated or a component is not ready.
These sounds
can also be generated more loudly with the built in siren.
options:
3 6 1
siren
chirps
enabled
3 6 0
siren
chirps
disabled
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled for alarms with parameter 320. Partial (split) arming is
always silent, if sequence 340 is selected. Chirp sounds can also be generated with the JA-60A wireless siren (self-
contained setting in the wireless siren).
8.19. Siren alarm in Disarm & Split arming or disarming
sequence: 3 7 x
The built in siren can be disabled for alarms during the Disarm or Partial & Split control panel arming (while somebody is
indoors). If the in siren is completely disabled for alarms with parameter 320, this setting is moot.
options:
3 7 1
alarm
enabled
3 7 0
alarm
disabled
Factory default setting: enabled