13. Monitoring station reporting codes table 

  

A two digit reporting code 

rc 

(00 to FFh) can be set for every event. If 00 is programmed as a report code, that event will 

not be reported.  
 The major events group is marked with 

Rc. 

When formats 3/1 or 4/1/1 are used, only these major events are reported to 

the Monitoring Station. This makes it necessary to only program the

 R 

digits. The second digit does not count. 

For Contact ID protocol, program code 11 for major events (

Rc

) which you want to report and the system will generate all 

details regarding the event automatically.  

 

Alarm system JA-60 “COMFORT” 

- 26 - 

MDY51319

 

N. Event 

Code 

001 Arming with remote control N.1 

Rc 

002 Arming with remote control N.2 

rc 

003 Arming with remote control N.3 

rc 

004 Arming with remote control N.4 

rc 

005 Arming with remote control N.5 

rc 

006 Arming with remote control N.6 

rc 

007 Arming with remote control N.7 

rc 

008 Arming with remote control N.8 

rc 

009 Arming with master code 

rc 

010 Arming with user code N.1 

rc 

011 Arming with user code N.2 

rc 

012 Arming with user code N.3 

rc 

013 Arming with user code N.4 

rc 

014 Arming with user code N.5 

rc 

015 Arming with user code N.6 

rc 

016 Arming with user code N.7 

rc 

017 Arming with user code N.8 

rc 

018 Arming with user code N.9 

rc 

019 Arming with user code N.10 

rc 

020 Arming with user code N.11 

rc 

021 Arming with user code N.12 

rc 

022 Arming with user code N.13 

rc 

023 Arming with user code N.14 

rc 

024 Partial arming 

Rc 

025 Quick arming without code 

Rc 

026 Disarming with remote control N.1 

Rc 

027 Disarming with remote control N.2 

rc 

028 Disarming with remote control N.3 

rc 

029 Disarming with remote control N.4 

rc 

030 Disarming with remote control N.5 

rc 

031 Disarming with remote control N.6 

rc 

032 Disarming with remote control N.7 

rc 

033 Disarming with remote control N.8 

rc 

034 Disarming with master code 

rc 

035 Disarming with user code N.1 

rc 

036 Disarming with user code N.2 

rc 

037 Disarming with user code N.3 

rc 

038 Disarming with user code N.4 

rc 

039 Disarming with user code N.5 

rc 

040 Disarming with user code N.6 

rc 

041 Disarming with user code N.7 

rc 

042 Disarming with user code N.8 

rc 

043 Disarming with user code N.9 

rc 

044 Disarming with user code N.10 

rc 

045 Disarming with user code N.11 

rc 

046 Disarming with user code N.12 

rc 

047 Disarming with user code N.13 

rc 

048 Disarming with user code N.14 

rc 

049 Entering of the programming mode 

Rc 

050 Exiting the programming mode 

Rc 

051 Communicator Reset 

Rc 

052 Initial AC powering 

Rc 

053 Alarm after initial AC powering 

Rc 

054 General battery trouble 

Rc 

055 General battery trouble end 

Rc 

056 Control panel battery trouble 

Rc 

057 Control panel battery trouble end 

Rc 

058 Zone alarm 1

 

Rc 

059 Zone alarm 2

 

rc 

060 Zone alarm 3

 

rc 

061 Zone alarm 4

 

rc 

062 Zone alarm 5

 

rc 

063 Zone alarm 6

 

rc 

064 Zone alarm 7

 

rc 

065 Zone alarm 8

 

rc 

066 Zone alarm 9

 

rc 

067 Zone alarm 10

 

rc 

068 Zone alarm 11

 

rc 

069 Zone alarm 12

 

rc 

070 Zone alarm 13

 

rc 

071 Zone alarm 14

 

rc 

072 Zone alarm 15

 

rc 

073 Zone alarm 16

 

rc 

074 Wrong access code alarm 

Rc 

075 Zone tamper 1

 

Rc 

076 Zone tamper 2

 

rc 

077 Zone tamper 3

 

rc 

078 Zone tamper 4

 

rc 

079 Zone tamper 5

 

rc 

080 Zone tamper 6

 

rc 

081 Zone tamper 7

 

rc 

082 Zone tamper 8

 

rc 

083 Zone tamper 9

 

rc 

084 Zone tamper 10

 

rc 

085 Zone tamper 11

 

rc 

086 Zone tamper 12

 

rc 

087 Zone tamper 13

 

rc 

088 Zone tamper 14

 

rc 

089 Zone tamper 15

 

rc 

090 Zone tamper 16

 

rc 

091 Keypad tamper 

rc 

092 Control panel tamper 

rc 

093 Siren tamper 

rc 

094 Zone fault 1

 

Rc 

095 Zone fault 2

 

rc 

096 Zone fault 3

 

rc 

097 Zone fault 4

 

rc 

098 Zone fault 5

 

rc 

099 Zone fault 6

 

rc 

100 Zone fault 7

 

rc 

101 Zone fault 8

 

rc 

102 Zone fault 9

 

rc 

103 Zone fault 10

 

rc 

104 Zone fault 11

 

rc 

105 Zone fault 12

 

rc 

106 Zone fault 13

 

rc 

107 Zone fault 14

 

rc 

108 Zone fault 15

 

rc 

109 Zone fault 16

 

rc 

110 Keypad fault 

rc 

111 Control panel fault 

rc 

112 Siren fault 

rc 

113 Zone alarm end 1 

Rc 

114 Zone alarm end 2

 

rc 

115 Zone alarm end 3

 

rc 

116 Zone alarm end 4

 

rc 

117 Zone alarm end 5

 

rc 

118 Zone alarm end 6

 

rc 

119 Zone alarm end 7

 

rc 

120 Zone alarm end 8

 

rc 

121 Zone alarm end 9

 

rc 

122 Zone alarm end 10

 

rc 

123 Zone alarm end 11

 

rc 

124 Zone alarm end 12

 

rc 

125 Zone alarm end 13

 

rc 

126 Zone alarm end 14

 

rc 

127 Zone alarm end 15

 

rc 

128 Zone alarm end 16

 

rc 

129 Zone tamper end 1 

Rc 

130 Zone tamper end 2

 

rc 

131 Zone tamper end 3

 

rc 

132 Zone tamper end 4

 

rc 

133 Zone tamper end 5

 

rc 

134 Zone tamper end 6

 

rc 

135 Zone tamper end 7

 

rc 

136 Zone tamper end 8

 

rc 

137 Zone tamper end 9

 

rc 

138 Zone tamper end 10

 

rc 

139 Zone tamper end 11

 

rc 

140 Zone tamper end 12

 

rc 

141 Zone tamper end 13

 

rc 

142 Zone tamper end 14

 

rc 

143 Zone tamper end 15

 

rc 

144 Zone tamper end 16

 

rc 

145 Keypad tamper end 

rc 

146 Control panel tamper end 

rc 

147 Siren tamper end 

rc 

148 Zone fault end 1 

Rc 

149 Zone fault end 2

 

rc 

150 Zone fault end 3

 

rc 

151 Zone fault end 4

 

rc 

152 Zone fault end 5

 

rc 

153 Zone fault end 6

 

rc 

154 Zone fault end 7

 

rc 

155 Zone fault end 8

 

rc 

156 Zone fault end 9

 

rc 

157 Zone fault end 10

 

rc 

158 Zone fault end 11

 

rc 

159 Zone fault end 12

 

rc 

160 Zone fault end 13

 

rc 

161 Zone fault end 14

 

rc 

162 Zone fault end 15

 

rc 

163 Zone fault end 16

 

rc 

164 Keypad fault end 

rc 

165 Control panel fault end 

rc 

166 Siren fault end 

rc 

167 Telephone line trouble 

Rc 

168 Telephone line trouble end 

Rc 

169 Control panel failure 

Rc 

170 End of control panel failure 

Rc 

171 Periodic test (24 hr. from last com.) 

Rc 

172 AC failure (in 30 min. after failure) 

Rc 

173 AC failure end  

Rc 

174 RF jamming 

Rc 

175 Wrong code alarm end 

Rc 

176 RF jamming end 

Rc 

177 Panic alarm  from remote control N.1  Rc 

178 Panic alarm from remote control N.2

 

rc 

179 Panic alarm from remote control N.3

 

rc 

180 Panic alarm from remote control N.4

 

rc 

181 Panic alarm from remote control N.5

 

rc 

182 Panic alarm from remote control N.6

 

rc 

183 Panic alarm from remote control N.7

 

rc 

184 Panic alarm from remote control N.8

 

rc 

185 Master code panic alarm 

rc 

186 User code panic alarm 

rc 

187 Panic alarm  end from remote contr. 1 Rc 

188 Panic alarm end from remote control N.2 rc 
189 Panic alarm end from remote control N.3 rc 
190 Panic alarm end from remote control N.4 rc 
191 Panic alarm end from remote control N.5 rc 
192 Panic alarm end from remote control N.6 rc 
193 Panic alarm end from remote control N.7 rc 
194 Panic alarm end from remote control N.8 rc 
195 Master code panic alarm end 

rc 

196 User code panic alarm end 

rc 

197 Subsystem panic alarm 

Rc 

198 Subsystem panic alarm end 

Rc 

Summary of Contents for JA-60 "Comfort"

Page 1: ...JA 60 COMFORT Alarm system Installation manual...

Page 2: ......

Page 3: ...dible indication 16 8 17 Entrance delay audible indication 16 8 18 Arming and disarming chirp sounds 16 8 19 Siren alarm in Disarm Split arming or disarming 16 8 20 Wireless siren alarm 17 8 21 Indica...

Page 4: ...on telephone line connection and servicing User is not allowed to open the cover and or make any modification 2 1 Opening of the control panel Fig 1 Press in the bottom tab via the small slot using a...

Page 5: ...l automatically recharge 2 7 Powering of the control panel Connect the Red wire connector over the Red terminal of the battery posi tive Reconnect the cable from the front panel to the main board insi...

Page 6: ...r opening should be in stant or delayed main entrance door Switch no 2 must stay in the OFF position See fig 8 check that all 3 terminals in the detector are connected together with short connecting l...

Page 7: ...are displayed as c1 to c8 on the LED display the system automatically recognizes and differentiates the controllers from detectors h To exit the enrolling mode press the N key a P will again be displ...

Page 8: ...nutes after the cover was attached the detector will enter its normal mode and its LED indicator will be switched off battery energy saving function Open and close the detector s cover to reset the te...

Page 9: ...bors when for example improp erly closed doors inside the house are repeatedly moved by the wind Such a bypass of problematic detector is reset with the disarming of the system This is the end of the...

Page 10: ...l also wirelessly trans mits the PGY signal and unit UC 216 can be used as a remote output of this signal see 19 C is a common contact of the alarm output relay max load 60V 1A The relay is turned on...

Page 11: ...l trigger the input Note if either the INP or TAMP terminal is not used it must be connected to the GND terminal The procedure to enroll the JA 60N with external sensors is identical as de scribed in...

Page 12: ...en alarm enabled 38x 381 YES 380 NO YES Indication of system problems when arming 39x 391 YES 390 NO NO Split control panel A B C sections 690x 6901 YES 6900 N0 NO Addressing of wireless detectors to...

Page 13: ...holding key 4 will erase all enrolled items detectors controllers siren and the sub system The JA 60A wireless siren will generate an enrollment signal when its power is switched on it will enroll to...

Page 14: ...programming 8 voice message recording and 89 dialer testing are ac cessible in the User mode see description from 9 1 to 9 3 options 2 5 1 changes enabled 2 5 0 changes disabled no programming in the...

Page 15: ...When this parameter is disabled these functions can be used only when followed by a code Master or User see the following table function setting 300 301 arming code F 1 partial arming F 2 code F 2 doo...

Page 16: ...This indication can be disabled with this setting options 3 5 1 indication enabled 3 5 0 indication disabled Factory default setting indication enabled 8 18 Arming and disarming chirp sounds sequence...

Page 17: ...the door after the system is armed options 3 9 1 warning enabled 3 9 0 warning disabled Factory default setting warning disabled 8 22 Control panel splitting sequence 690 x The control panel can be s...

Page 18: ...rs are addressed to section A 8 26 Automatic arming disarming setting sequence 64 nahhmm The control panel can automatically arm and disarm for a requested period of a day Up to ten instructions time...

Page 19: ...be terminated by pressing the N key To exit the programming mode press the N key P will turn off If any fault is indicated when you try to exit the programming mode the control panel will inform you a...

Page 20: ...ctor code F80 represents 0 end of message Note some Paging providers also offer an option to send the message as an SMS to the GSM network Consult your Paging provider for details if you have trouble...

Page 21: ...parameter x specifies which message will be sent x reaction 0 not to call 1 send message 1 and Pager code 2 send message 2 only 3 Send Pager code only 9 6 Telephone line checking sequence 9 9 x If th...

Page 22: ...2nd 3rd 4th 5th or 6th ring Note Remote access connection can also be enabled by the alarm system user regardless of the above setting by en tering code 89 during service or user mode when a remote c...

Page 23: ...s are sent later with lower priority A User or Installer can interrupt the digital dialer communication by entering the User mode or Programming mode Reset of the control panel has no influence to the...

Page 24: ...e End of alarm panic A Test 24 hour test Protocols x Name Hand shake Data Kiss off Speed format 0 Ademco Slow Si lent Knight 1400Hz 1900Hz 1400Hz 10bps Next table 1 Ademco Fast 1400Hz 1900Hz 1400Hz 14...

Page 25: ...F0 123456 F1 Phone number erasing 0 6 F 0 F y y is 1 to erase the main telephone number 2 to erase the back up telephone number Note Changing of a phone number erases the internal communicator s memor...

Page 26: ...amper 4 rc 079 Zone tamper 5 rc 080 Zone tamper 6 rc 081 Zone tamper 7 rc 082 Zone tamper 8 rc 083 Zone tamper 9 rc 084 Zone tamper 10 rc 085 Zone tamper 11 rc 086 Zone tamper 12 rc 087 Zone tamper 13...

Page 27: ...ers OK 094 1 300 Failure blown fuse in control panel or other general failure 052 3 300 Control panel powering 148 3 300 No failure in the system 172 1 301 AC failure 173 3 301 AC switched on 054 1 30...

Page 28: ...mote connection of a personal computer with Comlink software or a JA 60E keypad to a JA 60 con trol panel using a public telephone line It is necessary to know the access code for the remote control o...

Page 29: ...the reason of the trouble Press key N to disable beeping The trouble information is stored in the event memory and it can be reviewed entering F4 anytime in the future check the reason of the trouble...

Page 30: ...an be chained 1 An additional JA 60 or 65 control panel can be enrolled as a en works as an independent system However any event in the subsystem alarm tampering failure or low battery will trigger th...

Page 31: ...0 C built in sensor magnetic reed contact external sensor IN TAMP balanced lo J Motion tected It has built in tampering sensors and it uses digital processing of the signal for a high false alarm immu...

Page 32: ...king range is up to 30 meters RC 60 Remote control controls wirelessly the system by using other hardwired devices access systems ID chips cards reader etc It has two control inputs A and B and two wo...

Page 33: ...wireless button and JA 60 wireless detector s can be enrolled to generate Chime sound when the detector is triggered Power 230 V 1 5 W Communicating range up to 100 m Siren piezo 110dB Number of melo...

Page 34: ...e page at www jablotron com to download a beta version of it The software is a convenient way to setup the control panel to supervise the system which is on line to read view and store data from the e...

Reviews: