Alarm system JA-60 "COMFORT"
- 18 -
MDY51319
actions' table
a
no splitting
split system
0
no action
no action
1
arm all
arm all
2 disarm disarm
all
3
partial arming
arm A
4
partial arming
arm B
5 disarm disarm
A
6 disarm disarm
B
Notes:
•
If the control panel is not split, this setting has no effect.
•
Master code (MC) can not be addressed. If the system is split, the use of MC will arm all sections if no section is armed or it
will disarm all sections if any is armed. If no code arming is not used (sequence 300) and the system is spilt then entering F1
MC will effect only section A and entering F2 MC will effect only section B.
Example: to address user code number 4 to section A enter: 62 04 1
Factory default setting: all user codes (01 - 14) are addressed to section A
8.25. Addressing of wireless controllers to sections
sequence: 63 nns
If the control panel is split (see 8.21.), the wireless controllers (RC-11, RC-22 and JA-60D) can be addressed to A or B
section by entering:
63 nns
where:
nn
= number of the enrolled controller from 01 to 08 (c1 to c8)
s
= section: 1 = A, 2 = B
Notes:
•
If the control panel is not split, this setting has no effect
•
For the JA-60F keypad this setting has no effect (its user codes are determined by 62nns setting)
Example: to address controller number 5 to section A enter: 63 051
Factory default setting: all wireless controllers are addressed to section A
8.26. Automatic arming / disarming setting
sequence: 64 nahhmm
The control panel can automatically arm and disarm for a requested period of a day. Up to ten instructions (time & action)
can be programmed in the period of one day by entering:
64 nahhmm
where:
n
= instruction number from 0 to 9
a
= action (see the actions' table)
hh
= hours (from 00 to 23)
mm
= minutes (from 00 to 59)
Notes:
•
If any automatic action is selected, it will be preformed everyday in the programmed time, following the internal control panel clock
(see 8.26.).
•
The automatic arming and disarming can be overridden manually anytime (by an user code or a remote control)
•
If the control panel is in the requested arming mode before the action time, performance of the programmed action will not change
the arming
Example: to program an automatic complete arming of the system at 21:15 everyday enter: 64 0 1 21 15
Factory default setting: all instructions are set for no action
8.27. Real time and date setting
sequence: 4 hh mm dd MM YY
The control panel has a built in real time clock. All events are stored to the event memory including the time of the event.
The clock should be set after the installation is complete.
Time Setting:
4 hh mm dd MM YY
where
hh = hours
(24 hr. cycle)
mm = minutes
dd = day
MM = month
RR = year
Example: on Jun. 30 2005 at 17:15 enter: 4 17 15 30 06 05
After the control panel is powered, its internal clock’s default setting is: 00 00 01 01 00
Note: detail control panel event history can be viewed with a connected PC using Comlink software.