Alarm system JA-60 "COMFORT"
- 19 -
MDY51319
8.28. New service code setting
sequence: 5 nSC nSC
The Service Code can be used to enter the programming mode. A new Service Code must be entered twice in the se-
quence to avoid an error.
To change the code enter:
5 nSC nSC
where nSC is your new Service Code (four digits)
Example: to change service code to 1276 enter: 5 1276 1276
Factory default setting: service code is 6060
8.29. User Mode entering
Sequence: 6 9 9 9
This sequence is used to switch from the Service Mode to the User Mode, where you can set zones´ bypass (see User´s
manual). You can exit the User Mode by pressing the “N” button. The bypassed zones will remain active after the leaving
the User Mode.
9. Voice & Pager messages setting
A control panel equipped with a telephone dialer can automatically send a voice message(s) and a code to a Pager. The most conven-
ient programming of the dialer is via a connected PC using the Comlink software (see 14). Programming can also be performed by
entering programming sequences from the system keypad while in the control panel programming mode:
•
Enter the programming mode (entering
F 0 SC
- SC = Service Code, factory default SC=6060), indicated by a „P“ on the display.
This can only be done while the panel is disarmed.
•
The parameters of the dialer can be set by entering programming sequences from the keypad. Any unfinished programming se-
quence can be terminated by pressing the
N
key.
•
To exit the programming mode, press the N
key („P“ will turn off). If any fault is indicated when you try to exit the programming
mode, the control panel will inform you about the problem (see 8.20.).
•
Telephone numbers and the voice message can also be set up in the User Mode when enabled (see 8.6.2.)
List of the voice & Pager programmable parameters
Function sequence
options
factory d.
note
Dialing method
90x
901 = tone 900 = pulse
tone
Triggering of the dialer with a Panic alarm
91x
911 = YES 910 = NO
911
Triggering of the dialer with an Intruder alarm
92x
921 = YES 920 = NO
921
Triggering of the dialer with a Fire alarm
93x
931 = YES 930 = NO
931
Triggering of the dialer with a Tamper alarm
94x
941 = YES 940 = NO
941
Triggering of the dialer with a Technical alarm
95x
951 = YES 950 = NO
951
Telephone line checking enabled
99x
991 = YES 990 = NO
NO
Store telephone numbers for voice message
7xx..x F y
xx...x
= tel. number,
y
= mem-
ory 1 to 4, pause = F0
Pager dialing programming
7x.xF9z..zF5
x..x
= provider tel. number
z..z
= pager message
1:
2:
3:
4:
5:
Erase telephone number
7F0Fy
y
= memory 1 to 5, entering
7F0F0 erases all
Record voice message
8 0
(hold 0 and talk to control panel)
2 messages - see 9.2.
9.1. Telephone numbers entering
sequence: 7xxx....xxFy
Store telephone numbers for voice message entering:
7 xx... xx F y
where
xx...xx
= telephone number
y
= memory number from 1 to 4
A telephone number can have a maximum of 16 digits. A
pause
can be entered with
F0
(pause can not be entered as the first
digit).
Example: to store tel. number 483 123456 to memory no. 2 enter: 7 483 F0 123456 F2