5.4. Recording a detector’s location 

Alarm system JA-60 "COMFORT" 

- 9 - 

MDY51319 

  

After successfully testing all detectors, we recommend that you record the 

location of the sensors directly on the control panel (area under the LED dis-
play). A suitable marker for this is provided. If you need to erase your record, 
use a tissue dipped in rubbing alcohol. 

You can also record the location of the detectors on the user instruction 

card, and in the Comlink software as well.  (See software instructions) 
 

 

 

 

 

 

 

 

 

 

 

6. Finishing of the installation 

  

  Check that all detectors and other items have their covers attached. 

 

  If the control panel has a built in telephone dialer, record your voice mes-

sage and program the desired telephone numbers (see part 9). 

  We recommend to set the date and time in the control panel (see part 

8.21.); The control panel stores all events to an events list in its internal memory, including the date and time of the 
event. The details from the memory can be viewed any time in the future via a connected PC and Comlink software. 
The PC can also be used for convenient  setting of the control panel. 

Fig. 

13 

  The system has a factory default setting, which allows you to use it without any other additional programming. If you 

want to customize the control panel setting, see part 8. 

  Change the system Service Code to protect against unauthorized access to the programming mode (see part 8). 

 

Exit the programming

 mode by pressing the 

N

 key. The control panel will then enter the disarm mode. See the user 

instruction card for information on how to operate the system. 

  If you have troubles with your system, see the Trouble shooting table in part 17. 

 

Note: during testing and normal operation you should be aware of the following function: if four alarms are triggered  from 
the same detector during the arming period, the detector will be bypassed automatically for the rest of the arming period. 
This feature prevents unlimited number of alarms (and possible conflict with your neighbors!) when for example improp-
erly closed doors inside the house are repeatedly moved by the wind. Such a bypass of problematic detector is reset with 
the disarming of the system. 

 

This is the end of the basic installation procedure. 

 

6.1. Specifications: 

 

control panel power 

15V

, 0.2A, 50Hz (adapter SELV) 

back up battery 

12V, 1,3Ah 

back up power output 

13.8V, max. 50mA (permanent load), max. 1A (10 minutes) 

number of zones (detectors)  16 
number of controllers 

max. 8 

Notes for JA-60X dialer use in European countries: 

 

Equipment is listed under the name of product: Wireless 
alarm system JA-60 "Comfort" 
Equipment is designed to work with networks according to 
TBR 21 and tested according to EG 201 121 V1.1.3, Jan. 
2000 including Advisory Notes for following countries: Ger-
many, Norway, Switzerland 
Equipment was not tested according to advisory additional 
notes for: Greece, Portugal and Spain 
Equipment may have interworking difficulties with the local 
networks requiring current limitation as in France 
Italy's legislation requires that use of SDR is subject to li-
cense.

 

 

events memory 

127 latest events incl. date and time information 

built in siren 

116dB 

working frequency 

433.92 MHz (optional) 

RF approved according 

EN 300 220 

complies with  

EN 50131-1, 50131-6 

telephone dialer* 

voice message to 4 numbers 

 

numeric message to a Pager 

 

digital communication to a monitoring station  

approved according* 

TBR21 

electrical safety and EMC 

EN 41003 (EN 60065), ETS 360683 

working environment 

indoor use, -10 to +40°C 

 

* only for control panels equipped with the telephone dialer module 

 

* can be connected to analogue interfaces TBR 21/1998, EG 201 121 V1.13/2000, AS/ACIF S002/2001 (Australia) 

 

Hereby, Jablotron Ltd., declares that this JA-60

 

is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. 

Original  of the conformity assessment can be found at the web page www.jablotron.cz, section Technical support. 
 

Note: Dispose of batteries safely depending on the type of the batteries and local regulation. Although this product does not contain any harmful materi-
als we suggest you to return the product to the dealer or directly to the producer after usage.

Summary of Contents for JA-60 "Comfort"

Page 1: ...JA 60 COMFORT Alarm system Installation manual...

Page 2: ......

Page 3: ...dible indication 16 8 17 Entrance delay audible indication 16 8 18 Arming and disarming chirp sounds 16 8 19 Siren alarm in Disarm Split arming or disarming 16 8 20 Wireless siren alarm 17 8 21 Indica...

Page 4: ...on telephone line connection and servicing User is not allowed to open the cover and or make any modification 2 1 Opening of the control panel Fig 1 Press in the bottom tab via the small slot using a...

Page 5: ...l automatically recharge 2 7 Powering of the control panel Connect the Red wire connector over the Red terminal of the battery posi tive Reconnect the cable from the front panel to the main board insi...

Page 6: ...r opening should be in stant or delayed main entrance door Switch no 2 must stay in the OFF position See fig 8 check that all 3 terminals in the detector are connected together with short connecting l...

Page 7: ...are displayed as c1 to c8 on the LED display the system automatically recognizes and differentiates the controllers from detectors h To exit the enrolling mode press the N key a P will again be displ...

Page 8: ...nutes after the cover was attached the detector will enter its normal mode and its LED indicator will be switched off battery energy saving function Open and close the detector s cover to reset the te...

Page 9: ...bors when for example improp erly closed doors inside the house are repeatedly moved by the wind Such a bypass of problematic detector is reset with the disarming of the system This is the end of the...

Page 10: ...l also wirelessly trans mits the PGY signal and unit UC 216 can be used as a remote output of this signal see 19 C is a common contact of the alarm output relay max load 60V 1A The relay is turned on...

Page 11: ...l trigger the input Note if either the INP or TAMP terminal is not used it must be connected to the GND terminal The procedure to enroll the JA 60N with external sensors is identical as de scribed in...

Page 12: ...en alarm enabled 38x 381 YES 380 NO YES Indication of system problems when arming 39x 391 YES 390 NO NO Split control panel A B C sections 690x 6901 YES 6900 N0 NO Addressing of wireless detectors to...

Page 13: ...holding key 4 will erase all enrolled items detectors controllers siren and the sub system The JA 60A wireless siren will generate an enrollment signal when its power is switched on it will enroll to...

Page 14: ...programming 8 voice message recording and 89 dialer testing are ac cessible in the User mode see description from 9 1 to 9 3 options 2 5 1 changes enabled 2 5 0 changes disabled no programming in the...

Page 15: ...When this parameter is disabled these functions can be used only when followed by a code Master or User see the following table function setting 300 301 arming code F 1 partial arming F 2 code F 2 doo...

Page 16: ...This indication can be disabled with this setting options 3 5 1 indication enabled 3 5 0 indication disabled Factory default setting indication enabled 8 18 Arming and disarming chirp sounds sequence...

Page 17: ...the door after the system is armed options 3 9 1 warning enabled 3 9 0 warning disabled Factory default setting warning disabled 8 22 Control panel splitting sequence 690 x The control panel can be s...

Page 18: ...rs are addressed to section A 8 26 Automatic arming disarming setting sequence 64 nahhmm The control panel can automatically arm and disarm for a requested period of a day Up to ten instructions time...

Page 19: ...be terminated by pressing the N key To exit the programming mode press the N key P will turn off If any fault is indicated when you try to exit the programming mode the control panel will inform you a...

Page 20: ...ctor code F80 represents 0 end of message Note some Paging providers also offer an option to send the message as an SMS to the GSM network Consult your Paging provider for details if you have trouble...

Page 21: ...parameter x specifies which message will be sent x reaction 0 not to call 1 send message 1 and Pager code 2 send message 2 only 3 Send Pager code only 9 6 Telephone line checking sequence 9 9 x If th...

Page 22: ...2nd 3rd 4th 5th or 6th ring Note Remote access connection can also be enabled by the alarm system user regardless of the above setting by en tering code 89 during service or user mode when a remote c...

Page 23: ...s are sent later with lower priority A User or Installer can interrupt the digital dialer communication by entering the User mode or Programming mode Reset of the control panel has no influence to the...

Page 24: ...e End of alarm panic A Test 24 hour test Protocols x Name Hand shake Data Kiss off Speed format 0 Ademco Slow Si lent Knight 1400Hz 1900Hz 1400Hz 10bps Next table 1 Ademco Fast 1400Hz 1900Hz 1400Hz 14...

Page 25: ...F0 123456 F1 Phone number erasing 0 6 F 0 F y y is 1 to erase the main telephone number 2 to erase the back up telephone number Note Changing of a phone number erases the internal communicator s memor...

Page 26: ...amper 4 rc 079 Zone tamper 5 rc 080 Zone tamper 6 rc 081 Zone tamper 7 rc 082 Zone tamper 8 rc 083 Zone tamper 9 rc 084 Zone tamper 10 rc 085 Zone tamper 11 rc 086 Zone tamper 12 rc 087 Zone tamper 13...

Page 27: ...ers OK 094 1 300 Failure blown fuse in control panel or other general failure 052 3 300 Control panel powering 148 3 300 No failure in the system 172 1 301 AC failure 173 3 301 AC switched on 054 1 30...

Page 28: ...mote connection of a personal computer with Comlink software or a JA 60E keypad to a JA 60 con trol panel using a public telephone line It is necessary to know the access code for the remote control o...

Page 29: ...the reason of the trouble Press key N to disable beeping The trouble information is stored in the event memory and it can be reviewed entering F4 anytime in the future check the reason of the trouble...

Page 30: ...an be chained 1 An additional JA 60 or 65 control panel can be enrolled as a en works as an independent system However any event in the subsystem alarm tampering failure or low battery will trigger th...

Page 31: ...0 C built in sensor magnetic reed contact external sensor IN TAMP balanced lo J Motion tected It has built in tampering sensors and it uses digital processing of the signal for a high false alarm immu...

Page 32: ...king range is up to 30 meters RC 60 Remote control controls wirelessly the system by using other hardwired devices access systems ID chips cards reader etc It has two control inputs A and B and two wo...

Page 33: ...wireless button and JA 60 wireless detector s can be enrolled to generate Chime sound when the detector is triggered Power 230 V 1 5 W Communicating range up to 100 m Siren piezo 110dB Number of melo...

Page 34: ...e page at www jablotron com to download a beta version of it The software is a convenient way to setup the control panel to supervise the system which is on line to read view and store data from the e...

Reviews: