Alarm system JA-60 "COMFORT"
- 21 -
MDY51319
9.4. Dialing method
sequence: 9 0 x
Enter:
9 0 1
for
tone
dialing
9 0 0
for
pulse
dialing (this option is blocked for some countries)
Note: this dialing method setting is also valid for Monitoring station communications as well as remote PC access
Factory default: tone dialing
9.5. Telephone dialer triggering*
sequences: 9 y x
With sequences 91x to 95x you can select which alarms will trigger the telephone dialer to call and which ones will not.
Enter:
9 y x
where
Example: if the dialer should not call when the system is tampered with, enter 940
Factory default setting: all alarms will trigger the dialer (it means 911, 921, 931, 941 & 951)
If two different voice messages were recorded (see 9.2.), then parameter
x
specifies which message will be sent.
x
reaction
0
not to call
1
send message #1 and Pager code
2
send message #2 only
3
Send Pager code only
9.6. Telephone line checking
sequence: 9 9 x
If this function is enabled, the dialer will check regularly if the telephone line is ready to make a phone call. If the line is
not ready for more than 15 minutes, the control panel will indicate a telephone line failure (failure L). Not working tele-
phone line or a phone conversation or Internet connection longer than 15 minutes can cause a fault.
options:
9 9 1
checking
enabled
9 9 0
checking
disabled
Note: this setting is also valid when the dialer is used for Monitoring station communications as well as remote PC ac-
cess
Factory default setting: checking disabled
x reaction
0
not to call
1
voice message & Pager code
2
voice message only
3
Pager code only
y
alarm
1
Panic – silent
2
Intruder
3
Fire
4
Tampering
5
Technical trouble
Summary of Contents for JA-60 "Comfort"