12.2. Account code setting
sequence: 02
This sequence is used for the alarm system identification by a Monitoring Station. The sequence structure is as follows:
02 x x x x
xxxx
– account code ( x are numbers from 0 to 9 or hexadecimals).
When using only three-digit codes (formats 3/1 and 3/2) enter a zero in the first position. The communicator will then ig-
nore it (example - 0123)
Note: Changing of the account code erases the internal communicator’s memory of non reported events and sends a „Reset“ reporting
code (051) to the Monitoring Station.
Factory setting: 0000
12.3 Protocol and Format setting
sequence: 03
This sequence is used to select the communication protocol and format. Its structure is as follows:
03 x y
x
- protocol (0 – 9, see table bellow)
y
- format (0 - 3 see table on right
)
Formats
y
format
reports
structure
0
3/1
Major events only
xxx R
1
3/2
All events
xxx rc
2
4/1/1
Major events with autom.
source identification
xxxx Rn
3
4/2
All events
xxxx rc
xxxx
= account number
R
= major event code (first digit counts only)
rc
= detailed event code (two digits)
n
= source identification (generated automatically)
Surgard
protocol has structure:
xxxx E rc,
where
E is a group identifier (generated automatically)
E
Event
Note
1 Fire
2 Panic
3 Alarm General
4 Arming
Incl. Partial
5 Disarming
6 Failure
Mains failure, RF jamming etc..
8 Report
Enter/Exit service mode …
9 Restore
End of alarm, panic …
A Test
24 hour test
Protocols
x Name
Hand-shake Data Kiss
off
Speed
format
0
Ademco Slow
(Si-
lent Knight)
1400Hz 1900Hz
1400Hz
10bps
Next
table
1
Ademco Fast
1400Hz 1900Hz
1400Hz
14bps
Next
table
2
Telemax
2100Hz 1650Hz
2100Hz
10bps
Next
table
3
Franklin
2300Hz 1800Hz
2300Hz
20bps
Next
table
4
Radionics 2300
2300Hz 1800Hz
2300Hz
40bps
Next
table
5
Radionics 1400
1400Hz 1900Hz
1400Hz
40bps
Next
table
6
DTMF 2300
2300Hz DTMF
2300Hz
DTMF
Next
table
7
Surgard*
2300Hz DTMF
2300Hz
DTMF
4/3
8
Ademco express*
Dual tone
DTMF
1400Hz DTMF
4ID/2
9
Contact ID*
Dual tone
DTMF
1400Hz DTMF
CID
*
fixed format
, “y” is
arbitrary (0 is recommended)
Notes:
1/ Some Monitoring Station receivers do not support all formats.
2/ Logic of the format marking - 4/2 means, that an account code has
4 digits and an event report code has 2 digits.
Changing of a format erases the internal communicator’s memory of non reported events and sends a „Reset“ reporting code (051) to the
Monitoring Station.
Factory setting: 90 (Contac ID)
12.4. Re-dialing pause setting
sequence: 04
If a dialer is triggered it attempts to make a connection (altering the main and the backup telephone number). If it is not
possible to make a connection after 8 attempts, a pause is inserted. After this pause the dialer dials again. If any event
triggers the communicator during the pause, the pause ends immediately. The pause length can be set in a following
way:
0 4 x
x –
time multiplied by 10 minutes (from 1 to 9, example 3 = 30 minutes)
Factory setting: 1 = 10 min.