Alarm system JA-60 "COMFORT" 

- 13 - 

MDY51319 

  

8.2. Enrollment (teaching) of wireless items 

enter:

  

 1 

As a maximum 16 detectors and 8 controllers (remote controls & keypads) can be enrolled to the control panel. A wire-
less siren and an additional JA-6x control panel (subsystem) can be enrolled as well. 

 

 

press key

 

1

 (while „P“ is displayed) to enter the enrolling mode. The control panel will display the next free position to 

enroll a detector. 

 

Use key 1 and 6 to scroll

 (up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key-

pads) – A (wireless siren) – J (sub control panel JA-60, 65). The display shows the position number while the Battery 
LED indicates if the position is occupied (If the Battery LED is illuminated, it indicates that position is occupied). 

  Detectors and keypads are automatically enrolled when their power is switched on (batteries are installed). A remote 

control is enrolled only after both of its buttons are simultaneously pressed and held for 3 seconds. A subsystem con-
trol panel will enroll after sequence 299 is entered while it is in its programming mode. The system will not allow en-
rollment of an item into a non-corresponding position (a detector can not be enrolled into a controller position etc.). If 
you try to enroll an item into an incorrect position, the control panel will automatically select a suitable position. 

 

Control panel confirms enrollment

 with a „beep“ (press F to select a louder “beep” sound). The LED display will 

show the number of the enrolled item for 2 seconds and then it will display the number of the next free position.  

 

To change the position 

of an enrolled item is simple. 

Enroll it to the new selected position

 (the item will „move“). If 

you enroll an item to an occupied position, the former item will be deleted and only the new enrollment is valid. Only 
one item (detector, controller etc.) can be stored to each position. 

 

Erase an enrolled item

  the following way: in the enrolling mode select the corresponding position and then press 

and hold key 2 for two seconds. The item will be erased (confirmed with a long beep). If you press and hold key 3, all 
enrolled controllers (remote controls and keypads) will be erased. Pressing and holding key 4 will erase all enrolled 
items (detectors, controllers, siren and the sub system). 

 

The JA-60A wireless siren will generate an enrollment signal

 when its power is switched on (it will enroll to posi-

tion A). If you need to enroll a siren which is already powered and it is not possible to easily switch off its power, you 
can enroll it the following way: enter the enrolling mode and then enter the 6 digit siren production code (printed in the 
siren’s manual). The control panel will “request” the siren to send its enrollment signal. The siren will send the signal 
only if it has no current communication with any other control panel (This protects you from enrolling your neighbor’s 
siren). Enrollment is completed about five seconds after the code is entered. 

Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio sig-
nal as a weak one. Items are only enrolled if their radio signal has a level which guarantees reliable communication. 
Check the detector’s batteries and try to enroll the problematic sensor once more. If it is not accepted by the control 
panel, you should change the location of the item. All items should be located 1 m or more from the control panel. 

8.3. Exit delay  

sequence:

  2 0 x 

To change the duration of the exit delay enter  

20x     

(where 

x

 represents time in seconds x10). The delay can be selected from 10 to 90 seconds. 

Example: to select an Exit delay duration of 20 seconds, enter 202 

Factory default setting is 30 seconds 

 

8.4. Entrance delay 

sequence:  2 1 x 

To change duration of the entrance delay enter: 

 

21x 

  (where 

x

 represents time in seconds x10). The delay can be selected from 10 to 90 seconds. 

Example: To select entrance delay duration of 40 seconds, enter 214  

Factory default setting: 30 seconds 

 

8.5. Alarm duration  

sequence:  2 2 x 

The alarm duration can be selected from 1 to 8 or 15 minutes (or 10 seconds) entering 

22x

 (where 

x

 represents time in 

minutes, for x=0 the duration will be 10 seconds, for x=9 the duration will be 15 minutes). 

Example: to select an alarm duration of 5 minutes, enter 225 

Factory default setting is 4 minutes 

 

8.6. PgX and PgY outputs function 

sequences:  2 3 x  &   2 4 x 

The control panel outputs PgX and PgY can have different functions, depending on parameter 

x

 in the corresponding 

sequence: 

2 3 x

 – determines triggering of  

PgX

 

2 4 x

 – determines triggering of  

PgY 

Summary of Contents for JA-60 "Comfort"

Page 1: ...JA 60 COMFORT Alarm system Installation manual...

Page 2: ......

Page 3: ...dible indication 16 8 17 Entrance delay audible indication 16 8 18 Arming and disarming chirp sounds 16 8 19 Siren alarm in Disarm Split arming or disarming 16 8 20 Wireless siren alarm 17 8 21 Indica...

Page 4: ...on telephone line connection and servicing User is not allowed to open the cover and or make any modification 2 1 Opening of the control panel Fig 1 Press in the bottom tab via the small slot using a...

Page 5: ...l automatically recharge 2 7 Powering of the control panel Connect the Red wire connector over the Red terminal of the battery posi tive Reconnect the cable from the front panel to the main board insi...

Page 6: ...r opening should be in stant or delayed main entrance door Switch no 2 must stay in the OFF position See fig 8 check that all 3 terminals in the detector are connected together with short connecting l...

Page 7: ...are displayed as c1 to c8 on the LED display the system automatically recognizes and differentiates the controllers from detectors h To exit the enrolling mode press the N key a P will again be displ...

Page 8: ...nutes after the cover was attached the detector will enter its normal mode and its LED indicator will be switched off battery energy saving function Open and close the detector s cover to reset the te...

Page 9: ...bors when for example improp erly closed doors inside the house are repeatedly moved by the wind Such a bypass of problematic detector is reset with the disarming of the system This is the end of the...

Page 10: ...l also wirelessly trans mits the PGY signal and unit UC 216 can be used as a remote output of this signal see 19 C is a common contact of the alarm output relay max load 60V 1A The relay is turned on...

Page 11: ...l trigger the input Note if either the INP or TAMP terminal is not used it must be connected to the GND terminal The procedure to enroll the JA 60N with external sensors is identical as de scribed in...

Page 12: ...en alarm enabled 38x 381 YES 380 NO YES Indication of system problems when arming 39x 391 YES 390 NO NO Split control panel A B C sections 690x 6901 YES 6900 N0 NO Addressing of wireless detectors to...

Page 13: ...holding key 4 will erase all enrolled items detectors controllers siren and the sub system The JA 60A wireless siren will generate an enrollment signal when its power is switched on it will enroll to...

Page 14: ...programming 8 voice message recording and 89 dialer testing are ac cessible in the User mode see description from 9 1 to 9 3 options 2 5 1 changes enabled 2 5 0 changes disabled no programming in the...

Page 15: ...When this parameter is disabled these functions can be used only when followed by a code Master or User see the following table function setting 300 301 arming code F 1 partial arming F 2 code F 2 doo...

Page 16: ...This indication can be disabled with this setting options 3 5 1 indication enabled 3 5 0 indication disabled Factory default setting indication enabled 8 18 Arming and disarming chirp sounds sequence...

Page 17: ...the door after the system is armed options 3 9 1 warning enabled 3 9 0 warning disabled Factory default setting warning disabled 8 22 Control panel splitting sequence 690 x The control panel can be s...

Page 18: ...rs are addressed to section A 8 26 Automatic arming disarming setting sequence 64 nahhmm The control panel can automatically arm and disarm for a requested period of a day Up to ten instructions time...

Page 19: ...be terminated by pressing the N key To exit the programming mode press the N key P will turn off If any fault is indicated when you try to exit the programming mode the control panel will inform you a...

Page 20: ...ctor code F80 represents 0 end of message Note some Paging providers also offer an option to send the message as an SMS to the GSM network Consult your Paging provider for details if you have trouble...

Page 21: ...parameter x specifies which message will be sent x reaction 0 not to call 1 send message 1 and Pager code 2 send message 2 only 3 Send Pager code only 9 6 Telephone line checking sequence 9 9 x If th...

Page 22: ...2nd 3rd 4th 5th or 6th ring Note Remote access connection can also be enabled by the alarm system user regardless of the above setting by en tering code 89 during service or user mode when a remote c...

Page 23: ...s are sent later with lower priority A User or Installer can interrupt the digital dialer communication by entering the User mode or Programming mode Reset of the control panel has no influence to the...

Page 24: ...e End of alarm panic A Test 24 hour test Protocols x Name Hand shake Data Kiss off Speed format 0 Ademco Slow Si lent Knight 1400Hz 1900Hz 1400Hz 10bps Next table 1 Ademco Fast 1400Hz 1900Hz 1400Hz 14...

Page 25: ...F0 123456 F1 Phone number erasing 0 6 F 0 F y y is 1 to erase the main telephone number 2 to erase the back up telephone number Note Changing of a phone number erases the internal communicator s memor...

Page 26: ...amper 4 rc 079 Zone tamper 5 rc 080 Zone tamper 6 rc 081 Zone tamper 7 rc 082 Zone tamper 8 rc 083 Zone tamper 9 rc 084 Zone tamper 10 rc 085 Zone tamper 11 rc 086 Zone tamper 12 rc 087 Zone tamper 13...

Page 27: ...ers OK 094 1 300 Failure blown fuse in control panel or other general failure 052 3 300 Control panel powering 148 3 300 No failure in the system 172 1 301 AC failure 173 3 301 AC switched on 054 1 30...

Page 28: ...mote connection of a personal computer with Comlink software or a JA 60E keypad to a JA 60 con trol panel using a public telephone line It is necessary to know the access code for the remote control o...

Page 29: ...the reason of the trouble Press key N to disable beeping The trouble information is stored in the event memory and it can be reviewed entering F4 anytime in the future check the reason of the trouble...

Page 30: ...an be chained 1 An additional JA 60 or 65 control panel can be enrolled as a en works as an independent system However any event in the subsystem alarm tampering failure or low battery will trigger th...

Page 31: ...0 C built in sensor magnetic reed contact external sensor IN TAMP balanced lo J Motion tected It has built in tampering sensors and it uses digital processing of the signal for a high false alarm immu...

Page 32: ...king range is up to 30 meters RC 60 Remote control controls wirelessly the system by using other hardwired devices access systems ID chips cards reader etc It has two control inputs A and B and two wo...

Page 33: ...wireless button and JA 60 wireless detector s can be enrolled to generate Chime sound when the detector is triggered Power 230 V 1 5 W Communicating range up to 100 m Siren piezo 110dB Number of melo...

Page 34: ...e page at www jablotron com to download a beta version of it The software is a convenient way to setup the control panel to supervise the system which is on line to read view and store data from the e...

Reviews: