5. Testing of detectors and controllers
The control panel should be in the programming mode for testing – (LED display will show „P“ )(see part 8. how to enter
programming mode). If the control panel will not indicate a detector’s triggering during testing, it means that this detector
was not enrolled (see note in part 4.1.).
5.1. JA-60N magnetic door detector testing
•
Attach the detector’s cover (the detector will automatically enter a testing mode for 5 minutes)
•
Opening and closing of the door/window will be confirmed by the detector’s LED.
•
The control panel’s LED display will display the triggered detector’s number and it will make a beep - press F to select the
loudness of the beep (0-I-II).
•
5 minutes after the cover was attached, the detector will enter its normal mode and its LED indicator will be switched off
(battery energy saving function). Open and close the detector‘s cover to reset the testing mode for an additional 5 min-
utes, if needed.
5.2. JA-60P motion detector testing
•
Attach the detector's cover and wait until the LED turns off. From this moment the detector will be in its testing mode for 5
minutes and each detected movement will be confirmed by the detector's LED.
•
The control panel's LED display will display the triggered detector's number and it will make a beep - press F to select the
loudness of the beep (0-I-II).
•
Confirm that the detector covers the protected area as you expected (see diagram in fig. 11). If you need another cover-
age pattern (long corridor, pet zone), you can get an optional detector lens from your distributor.
•
5 minutes after the cover was attached, the detector will enter its normal mode and its LED indicator will be switched off
(battery energy saving function). Open and close the detector's cover to reset the testing mode for an additional 5 minutes
if needed.
fig.
11
Note: the motion detector, in normal operating mode, conserves battery energy. It will not indicate triggering with its
LED. It will also block the movement sensor for a period of 5 minutes after a movement is detected. This means that
when users are in the protected area and they move frequently in front of the detector, it will transmit information about
the movement to the control panel only once every 5 minutes. But when the users leave the area, the detector will be
ready for instant detection 5 minutes after the last triggering. This system significantly prolongs the life time of the batter-
ies.
To change the period, for which the sensor is blocked after triggering from 5 min. to 1 min., press and hold the detector’s
tamper switch when you install the batteries into it. This mode is suitable when you prefer more frequent transmissions of the
signal. However, the life time of the batteries will usually be shorter, depending on how frequently the detector is triggered.
5.3. Remote control and keypad testing
Alarm system JA-60 "COMFORT"
- 8 -
MDY51319
•
Press any button on the remote control (panic button) or enter a valid
code on the wireless keypad (1234 factory default setting)
•
The control panel’s LED display will display the controller’s number (c1 to
c8) and it will beep - press F to select the loudness of the beep (0-I-II).
•
This procedure allows you to test the remote control’s working range
•
The wire operated keypad, JA-60E, has identical functions as the con-
trol panel’s keypad.