APPENDX
A.2 COMMUNICATION PROBLEMS
When the machine is in OFF line, or, If a communication error occurs, the following default data will
appear on the display.
Default setting
000, 000, 027, 254
will be displayed at
B10-09-02: IP Address
Default setting
0000, 1bfe, 1001
will be displayed at
B10-09-03: MAC Address
Default setting
000, 000, 027, 254
will be displayed at
B10-09-04: Subnet Mask Address
Default setting
000, 000, 027, 254
will be displayed at
B10-09-05: Gateway Address
If this happens, check that the network environment (Ex. Ethernet cable, Hub, etc.) is normal.
When it is found normal, turn the power OFF and ON, or press the RESET key to confirm that the
following equation is made for each address.
B10-09-02=IP Address=B10-01
B10-09-03=MAC Address=B10-07
B10-09-04=Subnet Mask Address=B10-03
B10-09-05=Gateway Address=B10-02
Note that the function of B10-09: Status is for displaying the network connection status when the
power is turned OFF and ON, or the RESET key is pressed. It is not for updating the data in
real-time.
When using the machine in OFFLINE, this data can be neglected. However, when changing from
OFFLINE to ONLINE (Re-connection to network), confirm the above values after the power is
turned OFF and ON, or the RESET key is pressed
BC-4000TEC User’s Manual No. JBAW97EBC-4000TEC
A-3
Summary of Contents for BC-4000TEC
Page 19: ...Chapter 1 PRODUCT OVERVIEW BC 4000TEC User s Manual No JBAW07EBC 4000TEC 1 11 ...
Page 20: ......
Page 32: ...Chapter 3 SUBTRACTION MODE 3 4 BC 4000TEC User s Manual No JBAW97EBC 4000TEC ...
Page 112: ......
Page 122: ......
Page 126: ...APPENDX A 4 BC 4000TEC User s Manual No JBAW97EBC 4000TEC ...
Page 127: ......