CNC Base machinery / CNC machinery: Type FlatCom
Assembly instruction / Operating instruction for FlatCom Series M, L and XL
page 29
If the SCM recognizes standstill of all machinery axes and also standstill of the working
spindle, the
cover button
is enabled. In this state the cover can be unlocked by pressing
the cover button so the door / cover can be opened.
You can continue the execution of the user program by pressing the start button or you can
abort program execution by pressing the ESC button on the keyboard.
6 - Cover-button
Use this button to open the machines cover or safety door. This is only possible if the
conditions from point “8 – mode selection switch“ are complied. An enable for opening of
the cover or safety door is signalized by a white lighted cover button.
7 - ACK-button (ACKnowledge-button)
In the operation mode
TEST
this button has to be pushed as long as the machinery axes
are moving
and
the door / cover is open.
Releasing the
Acknowledge-button (ACK-Button)
when the door / cover is open causes
an EMERGENCY STOP and therewith a switch off the power voltage supply for the motor
power amplifiers and for the frequency converter(s) driving the working spindle(s).
8 - Mode selection switch
= key switch
Use this switch to change between
AUTO (processing mode)
and
TEST
(setup mode)
.
In
AUTO
you can
open
the
cover or safety door
of the machine
only
if
no axis is in motion
and the mounted
working spindle
is
switched off
(means that spindle does not turn).
In
TEST
you can
open
the
cover or safety door
of the machine
only
if the mounted
working spindle
is
switched off
(means that
spindle does not turn). You can just
move the axes at opened cover
or safety door
if you
press
the
ACK button
.
Ensure that in setup-mode (key switch on TEST) only authorized
personal operates on the machine.
In which operation mode the working spindle can be switched on ?
Operation mode AUTO = AUTOMATIC = Processing mode
Any switch on resp. turning on to target speed the working spindle
is possible
if the door /
cover is closed and locked
.
Operation mode TEST = TEST = Setup mode
Any switch on resp. turning on to target speed the working spindle
is generally
impossible
.