9 Cleaning, lubrication and maintenance
Switch off the main switch and unplug the mains plug before every
cleaning or maintenance to avoid an accidental switching on.
9.1
Cleaning
Clean the machine regularly with a hand brush or vacuum cleaner (no compressed air)
from all chips. This protects the mechanics from premature wear.
The seal lips include a Teflon component and require no special maintenance.
Clean the polycarbonate panes with a not scouring plastic cleaner.
9.2
Lubrication and maintenance
The guide rails and drive shafts are fitted from the factory with a long-term central
lubrication. Depending on the strain, you should regrease the guides and drive shafts in
an interval of about 500-1000 hours of operation. Please use the grease gun available
as accessories for centralized and the associated specialty grease.
If you use oil, please lubricate in an interval of about 100-200 hours of operation.
Lubricate not too much at once, the wave rails and steel rails must not swim in the
grease.
9.2.1 Basic lubrication
The drive components are lubricated at the factory with
isel
special grease. You can
immediately drive the axis.
The EC-Safety data sheet according directive 93/112/EU and ISO 11014-1 can be sent to
you on demand.
9.2.2 Later lubrication
For the lubrication of linear bearings with waves is only the
isel
special grease used.
Under the following article numbers the grease can be ordered:
299032 0002 grease cartridge
299032 0003 grease gun
Depending on the application is recommended that every 500 to 1000 operating hours you
have to lubricate the axles.
Unplug the power supply cable of the machine before each lubrication
process.