-184-
7 Control Mode
■
6060h (Modes of operation)
Index
6060h
Name
Modes of Operation
Setting
Condition
& Effective
Time
During
running &
Immediately
Data
Structure
VAR
Data
Type
int 8
Access
RW
Mapping
RPDO
Related
Mode
All
Value
Range
0 to 10 Default
0
Defines the mode of servo drive operation.
Value
Modes of Operation
0
N/A
Reserved
1
Profile Position Mode (PP)
See
2
N/A
Reserved
3
Profile Velocity Mode (PV)
See
4
Profile Torque Mode (PT)
See
5
N/A
Reserved
6
Homing Mode (HM)
See
7
Interpolated Position Mode (IP)
Not supported
8
Cyclic Synchronous Position Mode (CSP)
See
9
Cyclic Synchronous Velocity Mode (CSV)
See
"7.4 Cyclic Synchronous Velocity
10
Cyclic Synchronous Torque Mode (CST)
See
"7.5 Cyclic Synchronous Torque Mode
If an unsupported operation mode is set through SDO, an SDO error will be returned. For details, see
If an operation mode not supported is set through PDO, this operation mode is invalid.
■
6061h (Modes of operation display)
Index
6061h
Name
Modes of operation display
Setting
Condition
& Effective
Time
-
Data
Structure
VAR
Data Type
int 8
Access
RO
Mapping
TPDO
Related
Mode
All
Value
Range
0 to 10
Default
0
Displays the present operation mode of the servo drive.
Value
Modes of Operation
0
N/A
Reserved
1
Profile Position Mode (PP)
See
2
N/A
Reserved
3
Profile Velocity Mode (PV)
See
4
Profile Torque Mode (PT)
See
5
N/A
Reserved
6
Homing Mode (HM)
See
7
Interpolated Position Mode (IP)
Not supported
8
Cyclic Synchronous Position Mode (CSP)
See
9
Cyclic Synchronous Velocity Mode (CSV)
See
"7.4 Cyclic Synchronous Velocity
10
Cyclic Synchronous Torque Mode (CST)
See