Electrical Maintenance
95
7. If the 2FH and 2HP wires have good
continuity, check for battery voltage on the
2A-03 wire at the Fuel Heater Relay. If battery
voltage is not present, check the continuity of
2A-03 wire between the Fuel Heater Relay
and the 2A (J25) screw terminal on the base
controller. Also check to make sure the 2A-03
wire connection at the 2A (J25) screw
terminal is clean and tight.
8. If battery voltage is present on the 2A-03 wire
at the Fuel Heater Relay, check for battery
voltage on the 8FH-02 wire at the Fuel Heater
Relay. If battery voltage is not present, check
the continuity of 8FH-02 and 8FH-01 wires
between the Fuel Heater Relay and pin 7 in
the J16 connector on the base controller. Also
check to make sure the wire connections are
clean and tight.
9. If battery voltage is present on the 8FH-02
wire at the Fuel Heater Relay, check for a
defective Fuel Heater Relay.