![Ingersoll-Rand 070008 Maintenance Manual Download Page 73](http://html.mh-extra.com/html/ingersoll-rand/070008/070008_maintenance-manual_2060247073.webp)
Alarm Codes
72
31
Check Oil Pressure Switch
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
32
Refrigeration Capacity Low
The unit is no longer able to operate and has been shut
down. Repair immediately.
33
Check Engine RPM
Report alarm at end of day.
35
Check Run Relay Circuit
If unit is shut down repair immediately. Otherwise, report
alarm at end of the day.
(36)
Electric Motor Failed to Run
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
37
Check Engine Coolant Level
Check engine coolant level. Do not remove the cap if the
engine is hot. Report alarm at end of day.
38
Electric Phase Reversed
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
40
Check High Speed Circuit
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
42
Unit Forced to Low Speed
Report alarm at end of day.
44
Check Fuel System
Report alarm at end of day.
45
Check Hot Gas or Hot Gas Bypass
Circuit
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
46
Check Air Flow
Manually monitor load temperature. Report alarm at end of
the day.
48
Check Belts or Clutch
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
49
Check Spare Sensor 1
Report alarm at end of day.
50
Reset Clock
Report alarm at end of day.
52
Check Heat Circuit
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
53
Check Liquid Line Solenoid Circuit
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
54
Test Mode Timeout
Service Test or Output Test timed out after 15 minutes.
Report alarm at end of day.
56
Check Host Evap Fan Low Speed
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
57
Check Host Evap Fan High Speed
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
61
Low Battery Voltage
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
62
Ammeter Out of Calibration
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
(63)
Engine Stopped
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
64
Pretrip Reminder
Report alarm at end of day.
65
Abnormal Temperature Differential
Report alarm at end of day.
66
Low Engine Oil Level
Check engine oil level. If unit is shut down repair
immediately. Otherwise, report alarm at end of day.
67
Check Liquid Line Solenoid Circuit
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
COLOR CODE DEFINITIONS
OK TO RUN
CHECK AS SPECIFIED
TAKE IMMEDIATE ACTION
Num
Description
Operator Action