![Ingersoll-Rand 070008 Maintenance Manual Download Page 68](http://html.mh-extra.com/html/ingersoll-rand/070008/070008_maintenance-manual_2060247068.webp)
Operating Instructions
67
•
If the unit is currently operating in Electric
Mode the DIESEL MODE selection will
appear in the Main Menu.
Electric Mode Operation
If a unit equipped with the electric standby
SmartPower option is running in Diesel Mode, the
Diesel to Electric Auto-Switch feature is set NO
and the unit is connected to a source of standby
power, this feature allows the operator to
manually select electric mode operation. This
feature does not appear if the electric standby
SmartPower option is not installed or if the Diesel
to Electric Auto-Switch feature is set YES.
Diesel Mode Operation
If a unit equipped with the electric standby
SmartPower option is running in Electric Mode,
the Electric to Diesel Auto-Switch feature is set
NO, this feature allows the operator to manually
select diesel mode operation. This feature does
not appear if the electric standby SmartPower
option is not installed or if the Electric to Diesel
Auto-Switch feature is set YES.
Switching from Diesel to Electric
If the unit is running in Diesel Mode and the
Diesel to Electric Auto-Switch Enabled feature in
Guarded Access is set YES then the unit will
automatically switch to Electric Mode operation
when standby power is connected and available.
The screens shown below will not appear.
If the unit is running in Diesel Mode and the
Diesel to Electric Auto-Switch Enabled feature in
Guarded Access is set NO, the unit can be
switched to Electric Mode using the Electric
Standby selection from the Main Menu.
From the Standard Display, press the MENU Key
(Figure 140).
Figure 140: Menu Key
From the Main Menu choose Electric Standby and
press the SELECT Soft Key (Figure 141).
Figure 141: Select Key
If the unit has standby power available and is
turned on, the electric standby run screen will
appear. The new mode is confirmed for 10
seconds. The unit will start and run in Electric
Mode. If electric standby power is not available or
fails, the display will prompt for a return to Diesel
Mode as shown below.
Any engine related Shutdown Alarms become
Log Alarms when the unit is switched to Electric
Mode operation. If the unit is switched back to
Diesel Mode these alarms again become
Shutdown Alarms.
Electric Standby Power Fails or is
Disconnected
If the electric standby power source fails or is
disconnected and manual switching to Diesel
Mode is selected, the unit will prompt for a switch
to Diesel Mode (Figure 142).
Figure 142: Diesel Mode Prompt
•
Pressing the YES Soft Key will switch unit
operation back to Diesel Mode.
•
Pressing the NO Soft Key will allow the unit
to remain in Electric Mode even though
standby power is not available.
The unit will not run and Alarm Code 91 Check
Electric Ready Input will be set as a prevent
alarm.
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
ON
OFF
ON
OFF
MAIN MENU
DOWN
EXIT
SELECT
UP
HOURMETERS
MODE
ELECTRIC STANDBY
ADJUST BRIGHTNESS
ON
OFF
YES
NO
ELECTRIC STANDBY UNDETECTED
DO YOU WISH TO SWITCH TO
DIESEL?