Operating Instructions
50
Figure 75: Pretrip Submenu
Main Menu Choices
Each of these Main Menu choices will be
explained in following pages of this chapter:
Pretrip:
A Pretrip Test verifies unit operation.
Flash Drive:
If a properly configured USB Flash
Drive is currently connected to the USB Port on
the unit Control Panel, the Flash Drive Menu will
appear as a Main Menu selection.
Languages (If Enabled):
If more than one
language is enabled from the Guarded Access >
Language Menu, this menu item will appear.
Alarms:
The Alarm Menu allows the operator to
view any active alarms, and allows most alarms to
be cleared.
Gauges:
The Gauges Menu allows the operator to
view the unit gauges and I/O conditions
Sensors:
The Sensors Menu allows the operator
to view the unit and CargoWatch Data Logger
temperature sensors.
Data Logger (CargoWatch):
The CargoWatch Data
Logger is physically located in the HMI Control
Panel. It can support up to 6 optional temperature
sensors
Hourmeters:
The Hourmeters Menu allows the
operator to view the unit hourmeters that have the
view feature enabled in the Guarded Access
menu.
Mode:
The Mode Menu allows the operator to
change the unit operating modes that have been
enabled in Guarded Access.
Keypad Lockout:
If enabled in Guarded Access >
Main Menu Configuration, the keypad can be
locked to prevent unauthorized use.
Start Sleep Mode:
If this feature enabled in
Guarded Access > Main Menu Configuration, the
operator can select and set Sleep Mode from the
Mode Menu.
SmartPower™ Electric Standby Option:
The
Diesel/Electric Standby selection from the Main
Menu allows the operator to manually select
diesel or electric mode operation on units
equipped with the electric standby SmartPower
option.
Adjust Brightness:
The brightness of the HMI
Control Panel display can be adjusted to allow for
changing ambient light conditions.
Time:
The Time and Date held by the HMI
Control Panel can be checked. Time and Date
cannot be changed from the Main Menu.
Clear All ECU Faults:
Pressing this key will clear
all existing Engine Control Unit (ECU) Fault
Codes. NOTE: On C-600 units this is only
displayed on early versions of HMI software and
is not functional. It is not displayed on C-600
units with later versions of HMI software.
Pretrip
Pretrip Test verifies unit operation. This display
allows a Pretrip Test to be selected and initiated
by the operator. If the Pretrip Test is entered with
the unit shut down a Full Pretrip Test with device
amp checks will be performed. If the Pretrip Test
is entered with the unit running in either diesel or
electric mode a Running Pretrip Test is
performed. Test results are reported as PASS,
CHECK or FAIL when the Pretrip Test is
completed.
Pretrip Test Conditions
•
Current unit settings are saved and restored at
the end of the Pretrip Test or if the unit is
turned off and back on.
•
Pretrip Test can be run in either Diesel or
Electric Mode.
•
The unit will auto switch from Diesel Mode to
Electric Mode or from Electric Mode to Diesel
Mode during a Pretrip Test if these features
are enabled and the auto switch conditions
occur.
Conditions where Pretrip Tests are not
allowed
•
If any shutdown alarms are present. Pretrip
tests are allowed with some Check and Log
alarms.
ON
OFF
MAIN MENU
DOWN
EXIT
SELECT
UP
PRETRIP
LANGUAGE
ALARMS
GAUGES