Alarm Codes
74
129
Engine Run Time Maintenance
Reminder #2
Report alarm at end of day.
130
Electric Run Time Maintenance
Reminder #1
Report alarm at end of day.
131
Electric Run Time Maintenance
Reminder #2
Report alarm at end of day.
132
Total Unit Run Time Maintenance
Reminder #1
Report alarm at end of day.
133
Total Unit Run Time Maintenance
Reminder #2
Report alarm at end of day.
134
Controller Power On Hours
Report alarm at end of day.
141
Auto-Switch Diesel to Electric
Disabled
Report alarm at end of day.
143
Check Remote Zone Drain Hose
Heater Output (Zone shown if
Multi-Temp)
Report alarm at end of day.
144
Lost CAN Communications to
Expansion Module
Unit cannot operate and is shut down. Repair immediately.
145
Loss of Controller “On” 8XP
Feedback Signal
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
146
Software Version Mismatch
Report alarm at end of the day.
148
Auto-Switch Electric to Diesel
Disabled
Report alarm at end of day.
150
CargoWatch Sensor Out of Range
Low
Report alarm at end of day.
151
CargoWatch Sensor Out of Range
High
Report alarm at end of day.
152
CargoWatch Sensor Failed
Report alarm at end of day.
153
Expansion Module Flash Load
Failure
Report alarm at end of day.
157
OptiSet File Mismatch
Report alarm at end of day.
158
Primary Software failed to load
Report alarm at end of day.
159
Check Battery Condition
Report alarm at end of day.
160
Lost Radio Expansion Board (REB)
CAN Communication
Report alarm at end of day.
203
Check Display Return Air Sensor
Manually monitor load temperature. Report alarm at end of
day.
204
Check Display Discharge Air Sensor Manually monitor load temperature. Report alarm at end of
day.
233
REB Transitioning From
Conservative to Full Null
Report alarm at end of the day.
234
Check Relative Humidity Sensor
Report alarm at end of day.
251
REB Mis-configured
Report alarm at end of day.
252
Check Auto Fresh Air Exchange
Door
Report alarm at end of day.
500
Check Host Evaporator Fan Low
Speed
If unit is shut down repair immediately. Otherwise, report
alarm at end of day.
COLOR CODE DEFINITIONS
OK TO RUN
CHECK AS SPECIFIED
TAKE IMMEDIATE ACTION
Num
Description
Operator Action