Operating Instructions
63
Hourmeter Names and Definitions
Only configured hourmeters that have been
enabled in the Viewable Hourmeter Setup Menu
will be shown:
IMPORTANT: If a programmable hourmeter is
not enabled or the view for that hourmeter is not
turned on it will not appear in the display
sequence.
Mode
The Mode Menu allows the operator to change the
unit operating modes that have been enabled in
Guarded Access. Only Operating Modes that have
been enabled from the Guarded Access > Main
Menu Configuration Menu will be shown.
•
Turns Off Cycle Sentry Mode/Turns On Cycle
Sentry Mode (If Cycle Sentry is turned Off
unit runs in Continuous). Note that selecting
Cycle Sentry Mode or Continuous Mode can
also be accomplished using the Cycle Sentry
Key to the right of the display.
•
Allows temperature to be displayed in either
Fahrenheit or Celsius degrees (if enabled from
the Guarded Access > Main Menu
Configuration Menu).
•
Allows the optional Fresh Air Exchange door
to be opened or closed (if enabled from the
Guarded Access > Hardware Configuration
Menu).
•
Allows Keypad Lockout to be selected (if
enabled from the Guarded Access > Main
Menu Configuration Menu).
•
Start Sleep Mode (if enabled from the
Guarded Access > Main Menu Configuration
Menu).
When shipped from the factory, only the Cycle
Sentry/Continuous Mode is enabled.
If OptiSet Plus is in use some modes may not be
available.
To return to the Main Menu press the EXIT Key.
To return to the Standard display press the EXIT
Key again.
Using the Change Mode Menu
Mode changes are made using the Mode Menu.
From the Standard Display, press the MENU Key
(Figure 128).
Figure 128: Menu Key
The Main Menu will appear. Press the UP or
DOWN Key as required to choose the Mode
Menu. When the Mode Menu is selected, press the
SELECT Key to choose the Mode Menu (Figure
129).
Hourmeter
Name
Definition
Total Hours
Total number of hours the unit has been
turned on (protection hours).
Total Run
Time Hours
Total number of hours the unit has run in
both diesel and electric mode.
Engine Hours
Total number of hours the unit has run in
diesel mode.
Electric Run
Hours
Total number of hours the unit has run in
electric mode.
Total Run
Reminder 1
User Programmable - The number of
hours before a Total Unit Run Time
Maintenance Reminder 1 occurs.
Total Run
Reminder 2
User Programmable - The number of
hours before a Total Unit Run Time
Maintenance Reminder 2 occurs.
Controller
Power On
Total hours the controller and HMI Control
Panel have been turned on.
Pretrip
Reminder
User Programmable - number of hours
before a Pretrip Reminder occurs.
Engine
Reminder 1
User Programmable - The number of
hours before an Engine Run Time
Maintenance Reminder 1 occurs.
Engine
Reminder 2
User Programmable - The number of
hours before an Engine Run Time
Maintenance Reminder 2 occurs.
Electric
Reminder 1
User Programmable - The number of
hours before an Electric Run Time
Maintenance Reminder 1 occurs.
Electric
Reminder 2
User Programmable - The number of
hours before an Electric Run Time
Maintenance Reminder 2 occurs.