Alarm Codes
76
548
Battery Charger Temp Below
Operating Range
Report alarm at end of day.
549
Battery Charger Input AC
Overvoltage
Report alarm at end of day.
550
Battery Charger Internal
Overvoltage Fault
If unit is shut down repair immediately. Otherwise, report
alarm at end of the day.
551
Battery Charger Internal Temp
Sensor Fault
Report alarm at end of day.
552
Battery Charger Charging - Low
Battery
Report alarm at end of day.
553
Battery Charger Operating Derated
Due To High Temp Condition
Report alarm at end of day.
599
Engine Service Tool Connected
Maintenance information only. Report alarm at end of the
day.
COLOR CODE DEFINITIONS
OK TO RUN
CHECK AS SPECIFIED
TAKE IMMEDIATE ACTION
Num
Description
Operator Action