Operating Instructions
45
If YES is selected then the display will briefly
show the screen in Figure 58.
Figure 58: Yes Selected
Diesel Mode operation will briefly be confirmed.
If unit operation is required the diesel engine will
start as shown previously under STARTING THE
DIESEL ENGINE.
If the Electric to Diesel Auto-Switch Enabled
feature in Guarded Access is set NO then the unit
can also be switched from Diesel mode to Electric
mode operation using the Diesel Selection from
the Main Menu as shown later in this section.
Initiating a Manual Defrost
Cycle
Defrost cycles are usually initiated automatically
based on time or demand. Manual defrost is also
available
Manual defrost is available if the unit is running
and the evaporator coil temperature is less than or
equal to 45 F (7 C).
NOTE: If the Rail Alternate feature is set YES
defrost is allowed with an evaporator coil
temperature less than or equal to 55 F (13 C).
Other features such as door switch settings may
not allow manual defrost under some conditions.
To initiate a manual defrost cycle, press the
Defrost Key (Figure 59).
Figure 59: Press Defrost Key
The display briefly shows [DEFROST],
[PROGRAMMING DEFROST - PLEASE
WAIT] and then [DEFROST STARTED] (Figure
60).
Figure 60: Defrost Started
The display then shows the Defrost display. The
bar indicator shows approximately how much
time remains to complete the defrost cycle. The
bar indicator shows that the defrost cycle is about
25% complete (Figure 61).
Figure 61: Bar Indicator
If conditions do not allow a defrost cycle, the
display shown in Figure 62 will briefly appear.
The display will then return to the Standard
Display.
Figure 62: Defrost Not Available
See Figure 63 for an overview of the
Initiating a
Manual Defrost Cycle
procedure.
PROGRAMMING DIESEL MODE
PLEASE WAIT
ON
OFF
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
DEFROST STARTED
ON
OFF
35
MENU
SET
SENSORS
GAUGES
POINT
ON
OFF
ON
OFF
DEFROST NOT AVAILABLE