NSM-8×1AES/NSM-7×2AES Installation and Operation Manual
71
Appendix B: Resource Module X-Y Network Communication
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Expected Response
None
Examples
Table B-8
shows typical
Crosspoint Preset
commands and describes
the resulting actions that take place.
[:I<ID>]
Optional parameter used to specify
the ID/ address of the device/panel
requesting the
Crosspoint Preset
(valid id = 0 – FFF0 ). If the
destination specified is protected this
information will be used in
determining whether or not the
issuing user may execute the preset
crosspoint. If this parameter is left
off and the requested destination is
protected or if the ID is different than
the ID of the device that requested
the destination be protected, the
Crosspoint Preset
will not be
executed.
Closing
Carriage return
Table B-8.
Typical Command Examples
Command Sent
Action
@ P:014/4,1F:IA
Presets the following crosspoints:
Levels 0, 1, and 4
Destination 4
Source 31 (hex. 1F)
Device ID 10 (hex A)
Table B-7. Crosspoint Preset
Command Syntax
(Continued)
Command Syntax
Element
Syntax Format Description