NSM-8×1AES/NSM-7×2AES Installation and Operation Manual
61
Appendix B: Resource Module X-Y Network Communication
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Connecting the Frame
Follow these steps to connect a NEO frame to the X-Y network:
1. Connect all input and output sources to the frame.
All sources should be timed to be within one line of each other.
2. Connect the control device(s) to the appropriate ports (
LCN
and/or
Ethernet
) on the frame's rear panel.
3. Configure the NEO Frame IP Address.
The information for this procedure is described in the section
entitled “Setting the IP Address of a CCS Device,” found in
Chapter 9: Configuring CCS Devices of
CCS Pilot/Co-Pilot/
Navigator User Manuals
. (The CCS device to configure is the
3901RES-E module.)
4. Connect the additional frames using the
LCN
(X-Y) port if the
router is to be used in a multiple frame system.
5. Locate
SW4 DIP 6
on the 3901RES-E resource module(s) and
ensure that the switch is in the
On
position.
6. If the router is at the end of the X-Y bus, terminate the other X-Y
connector with a coaxial 75
Ω
terminator.