RJ150-30 / Operations and Maintenance Manual
Mobile Aircraft Air Conditioner
Trailer Mounted, Cool Mode Only
______________________________________________________________________________
JANUARY 20, 2004
SECTION 2 - 1
PAGE 23
Table 4. Boiling Temperatures of Water at Converted Pressure
Temperature
(
°°
F)
Inches of Vacuum
Microns*
Pressure
(Lbs/in
2
or psi
)
212
0.00
759,969
14.696
205
5.00
535,000
12.279
194
9.81
425,526
10.162
176
16.02
355,092
6.866
158
20.80
233,680
4.519
140
24.12
149,352
2.888
122
26.36
92,456
1.788
104
27.83
55,118
1.066
86
28.75
31,750
.614
80
29.00
25,400
.491
76
29.10
22,860
.442
72
29.20
20,320
.393
69
29.30
17,780
.344
64
29.40
15,240
.295
59
29.50
12,700
.246
53
29.60
10,160
.196
45
29.70
7,620
.147
32
29.82
4,572
.088
21
29.90
2,540
.049
6
29.95
1,270
.0245
-9
29.97
500
.019685
-24
29.99
254
.0049
-35
29.995
127
.00245
-60
29.999
25.4
.00049
-70
29.9995
12.7
.00024
-90
29.9999
2.54
.000049
* Remaining pressure in system in microns.