5
BRidgE ConnECtion SEttingS
5-14
Bridge Connection screen
Bridge Connection Settings > Bridge Connection
■
AMBE+2 Vocoder Assignment
4
Voice Protocol
(For Port Connection) ��
Set the voice protocol for the port connection to “g.711u,” “Protocol
for transceiver and SiP Phone Connection,” “Bridge Protocol,” or
“AMBE+2.”
(default for RoiP gateway 1 ~ 8: g.711u,
for Converter Bridge 1 ~ 20: g.711u)
L
“Protocol for transceiver and SiP Phone Connection” can be selected only
with the Converter Bridge 1 ~ 20.
L
if you connect to the iP1000C, set this item to “Protocol for transceiver and
SiP Phone Connection.”
L
if you connect to the VE-Pg4, set this item to “Bridge Protocol.”
5
AMBE+2 Vocoder
Assignment �������
Settable only when the Voice Protocol (
4
) is set to AMBE+2.
Select an AMBE+2 Vocoder from “not Assigned,” “internal,” or “Ct-24.”
(default for digital transceiver 1 ~ 4 (d-tRX1 ~ 4) : internal)
•
Internal
: Assignable up to 4 ports.
•
CT-24
: Assignable up to 2 ports. (the optional Ct-24 is required.)
L
The AMBE+2 Vocoder for the Digital Transceiver 1 ~ 4 (D-TRX1 ~ 4) is fixed
to the internal vocoder.
L
When the settings of Bridge Connection Source and Bridge Connection
destination are set as the digital transceiver in [Bridge Connection] setting
(Bridge Connection Settings > Bridge Connection > Bridge Connection), this
item is not displayed.
6
<Apply> ��������
Click to apply the entries.
7
<Reset> ��������
Click to reset the settings.
L
You cannot restore after clicking <Apply>.
6
7
4
5
1
2
3