7
CONNECTION PORT SETTINgS
7-37
EXT I/O (EXT) screen
Connection Port Settings > EXT I/O (EXT)
■
EXT Input Settings
6
Input Connection Port
Select the port which outputs the received audio signal.
(Default: IP Network)
•
EXT Output
:
Sends the audio signal to the devices that are connected to
EXT1 ~ EXT4 ports.
•
IP Network
:
Sends the audio signal to the devices that are connected
to the RoIP gateway through the IP network.
•
Emergency
:
Sends the audio signal to the device that is specifi ed as
the emergency call destination in the
“Emergency Notification.”
(Expert Settings > Emergency Notification)
L
Emergency communication has priority over normal
communication.
L
The RoIP gateway enters the Emergency mode when
the option selected in the Input Control (
8
) of the EXT1
~ EXT4 ports
are satisfi ed.
L
In the Emergency mode, all ongoing communication
routes, other than that for the Emergency Notice, are
disconnected.
L
To transmit the call as the Emergency Notice:
•
Confi rm the “Bridge Communication Source” is set to
“Emergency Notification.”
(Bridge Connection Settings > Bridge Connection >
Bridge Connection > Bridge Connection Source)
•
Confi rm the “Bridge Communication Destination” is set
to “Custom Bridge Connection.”
(Bridge Connection Settings > Bridge Connection >
Bridge Connection > Bridge Communication Destination)
•
Confi rm the “Emergency Notification Equipment” is set
to “Enable.”
(Expert Settings > Emergency Notifi cation >
Emergency Notifi cation >
Emergency Notification Equipment)
6
7
8
9
10
11
12
13
14
15
16
17