7
CONNECTION PORT SETTINgS
7-61
RoIP gateway screen
Connection Port Settings > RoIP gateway
■
Bridge Communication
The settings for the Bridge Communication when a Bridge Connection Destination is set to “Custom Bridge Connection.”
(Bridge Connection Settings > Bridge Connection > Bridge Connection > Bridge Connection Destination)
1
Encryption
Select whether or not to enable the Encryption function, depending on
the connected transceiverʼs setting.
(Default: Disable)
When you enable the function, enter an encryption key between 1 and
32767.
(Default: 1)
2
TalkBack
Select whether or not to enable the TalkBack function with devices
connected to the RoIP gateway.
(Default: Enable)
When the function is enabled, Select the TalkBack time.
(Default: 5)
• Range: 1 ~ 10 (seconds)
3
Call Type
Select a call type.
(Default: group)
• Options: Individual, group, or All
4
Destination Prefix ID
Enter a destination prefix ID.
The ID may differ, depending on the
system.
• Range: 0 ~30
5
Destination ID
Enter an Individual or group ID for the destination transceiver between
1 and 9999999.
(Default: 1)
L
Enter an ID between 00001 and 99999 when the Destination Prefix ID (
4
) is
entered.
6
Source ID
Enter the stationʼs source ID between 1 and 9999999. Used for calling
transceivers connected to the serial port.
(Default: 1)
7
<Apply>
Click to apply the settings.
8
<Reset>
Click to reset the settings.
L
You cannot reset after clicking <Apply>.